Learn More
PURPOSE The primary objective of this study is to perform a blinded evaluation of a group of retrospective image registration techniques using as a gold standard a prospective, marker-based registration method. To ensure blindedness, all retrospective registrations were performed by participants who had no knowledge of the gold standard results until after(More)
We developed a novel computer-aided detection (CAD) algorithm called the surface normal overlap method that we applied to colonic polyp detection and lung nodule detection in helical computed tomography (CT) images. We demonstrate some of the theoretical aspects of this algorithm using a statistical shape model. The algorithm was then optimized on simulated(More)
Measuring the properties of the white matter pathways from retina to cortex in the living human brain will have many uses for understanding visual performance and guiding clinical treatment. For example, identifying the Meyer's loop portion of the optic radiation (OR) has clinical significance because of the large number of temporal lobe resections. We use(More)
Diagnostic radiology requires accurate interpretation of complex signals in medical images. Content-based image retrieval (CBIR) techniques could be valuable to radiologists in assessing medical images by identifying similar images in large archives that could assist with decision support. Many advances have occurred in CBIR, and a variety of systems have(More)
Magnetic resonance diffusion-weighted imaging coupled with fiber tractography (DFT) is the only non-invasive method for measuring white matter pathways in the living human brain. DFT is often used to discover new pathways. But there are also many applications, particularly in visual neuroscience, in which we are confident that two brain regions are(More)
Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and less invasive alternative to FOC. It(More)
A method of computing the velocity field and pressure distribution from a sequence of ultrafast CT (UFCT) cardiac images is demonstrated. UFCT multi-slice cine imaging gives a series of tomographic slices covering the volume of the heart at a rate of 17 frames per second. The complete volume data set can be modeled using equations of continuum theory and(More)
(a) (b) (c) (d) Figure 1: These four volume renderings utilize a fully opaque transfer function, but are segmented using the method discussed in this paper. The segmented volumes show: (a) abdominal aortic branch vessels, (b) an aortic aneurysm, (c) an aorta, and (d) peripheral blood vessels in the lung. The yellow arrows indicate the location of the user's(More)
Since the introduction of Computed Tomographic Colonog-raphy (CTC), research has mainly focused on visualization and navigation techniques. Recently, efforts have shifted towards computer aided detection (CAD) of polyps. We propose a new approach to CAD in CT images that attempts to model the way a radiologist recognizes a polyp using optical flow fields(More)
This paper presents a new reference data set and associated quantification methodology to assess the accuracy of registration of computerized tomography (CT) and magnetic-resonance (MR) images. Also described is a new semiautomatic surface-based system for registering and visualizing CT and MR images. The registration error of the system was determined(More)