Implementation of Intensity Modulation Radiotherapy (IMRT) and patient dose verification was carried out with film and I'mariXX using linear accelerator with 120-leaf Millennium dynamic multileaf collimator (dMLC). The basic mechanical and electrical commissioning and quality assurance tests of linear accelerator were carried out. The leaf position accuracy(More)
The use of megavoltage X-ray sources of radiation, with their skin-sparing qualities in radiation therapy, has been proved useful in relieving patient discomfort and allowing higher tumor doses to be given with fewer restrictions due to radiation effects in the skin. The purpose of this study was to compare the dosimetric characteristics of a physical and(More)
Endometrial carcinoma is the most common malignancy arising in the female genital tract. Intracavitary vaginal cuff irradiation may be given alone or with external beam irradiation in patients determined to be at risk for locoregional recurrence. Vaginal cylinders are often used to deliver a brachytherapy dose to the vaginal apex and upper vagina or the(More)
Intracavitary brachytherapy is an integral part of radiotherapy for locally advanced gynecologic malignancies. A dosimetric intercomparison of high dose rate intracavitary brachytherapy (HDR_BT) and intensity-modulated radiotherapy in cervical carcinoma has been made in the present study. CT scan images of 10 patients treated with HDR_BT were used for this(More)
In this study, absorbed doses were measured and compared for high-energy electrons (6, 9, 12, 16, and 20 MeV) using International Atomic Energy Agency (IAEA), Technical Reports Series No. 277 (TRS), TRS 381, and TRS 398 dosimetry protocols. Absolute dose measurements were carried out using FC65-G Farmer chamber and Nordic Association of Clinical Physicists(More)
The purpose of this study is to examine the plan quality and monitor unit with sliding window IMRT and RapidArc (RA) treatment plans using American Association Physicists in Medicine TG119 test suite DICOM-RT images and structure sets. The structure set includes multi-target (superior, central, inferior), prostate, head and neck and C-shape. Plans were(More)
The advent of modern technologies in radiotherapy poses an increased challenge in the determination of dosimetric parameters of small fields that exhibit a high degree of uncertainty. Percent depth dose and beam profiles were acquired using different detectors in two different orientations. The parameters such as relative surface dose (D S), depth of dose(More)
To analyze backscattered dose enhancements near different metallic interfaces for cobalt-60 (60Co) gamma rays and 6- and 18-MV photon beams. Measurements were carried out with a PTW thin-window, parallel-plate ionization chamber and an RDM-1F electrometer. Thin sheets of aluminum, mild steel, copper, cadmium and lead were used as inhomogeneities. The(More)
P3 A NEW VERTEBRAL IMPLANT ALLOWING FOR PERCUTANEOUS VERTEBRAL ANATOMICAL RESTORATION DURING VERTEBRAL STABILISATION. PRELIMINARY CLINICAL EXPERIENCE ON 25 PATIENTS AFTER TRAUMATIC BURST FRACTURE AFTER 6 MONTHS FOLLOW UP. X Barreau, C Renaud, E Durandeau, S Luc, S Hansen, JM Vital, V Dousset Service de Neuroradiologie Interventionnelle et Diagnostique,(More)