Learn More
OBJECTIVE As the need for objective measures with cochlear implant users increases, it is critical to understand how electrical potentials behave when stimulus parameters are systematically varied. The purpose of this study was to record and evaluate the effects of implanted electrode site and stimulus current level on latency, amplitude, and threshold(More)
OBJECTIVE To evaluate effects of hearing mode (normal hearing, cochlear implant, or hearing aid) on everyday communication among adult unilateral listeners using the Speech, Spatial and Qualities of Hearing Scale (SSQ). Individuals with one good, naturally hearing ear were expected to have higher overall ratings than unilateral listeners dependent on a(More)
OBJECTIVE This pilot study examined speech recognition, localization, temporal and spectral discrimination, and subjective reports of cochlear implant (CI) recipients with unilateral deafness. STUDY DESIGN Three adult male participants with short-term unilateral deafness (<5 yr) participated. All had sudden onset of severe-to-profound hearing loss in 1(More)
OBJECTIVE Bilateral severe to profound sensorineural hearing loss is a standard criterion for cochlear implantation. Increasingly, patients are implanted in one ear and continue to use a hearing aid in the nonimplanted ear to improve abilities such as sound localization and speech understanding in noise. Patients with severe to profound hearing loss in one(More)
With today's technology and the demonstrated success of cochlear implantation, along with expanded candidacy criteria, the opportunity to provide optimal hearing to both ears for individuals with severe-to-profound hearing loss is greater than ever. This article reviews the advantages of binaural hearing and the disadvantages of hearing with only one ear or(More)
OBJECTIVE HiRes (HR) 120 is a sound-processing strategy purported to offer an increase in the precision of frequency-to-place mapping through the use of current steering. This within-subject study was designed to compare speech recognition as well as music and sound quality ratings for HR and HR 120 processing. SETTING Cochlear implant/tertiary referral(More)
OBJECTIVE The purpose of this study was to compare the electrically evoked auditory brain stem response (EABR) for lateral and medial placement of the Clarion HiFocus cochlear implant electrode array via the electrode positioning system (EPS). DESIGN Twenty-five adult and pediatric cochlear implant recipients participated in the study. Intraoperatively(More)
OBJECTIVE The purpose of this study was to intraoperatively record the electrically evoked auditory brainstem response (EABR) before and after placement of the electrode positioning system (EPS) (CII Bionic Ear with HiFocus I cochlear implant electrode array) as well as before and after stylet removal (Nucleus Contour cochlear implant electrode array). It(More)
OBJECTIVE Traditionally, children are cochlear implant (CI) candidates if bilateral severe to profound hearing loss is present and amplification benefit is limited. The current study investigated abilities of adolescents with asymmetric hearing loss (one ear with severe to profound hearing loss and better hearing contralaterally), where the poorer ear(More)