Identifying tumour margins during breast-conserving surgeries is a persistent challenge. We have previously developed miniature needle probes that could enable intraoperative volume imaging with optical coherence tomography. In many situations, however, scattering contrast alone is insufficient to clearly identify and delineate malignant regions. Additional(More)
In situ imaging of alveoli and the smaller airways with optical coherence tomography (OCT) has significant potential in the assessment of lung disease. We present a minimally invasive imaging technique utilizing an OCT needle probe. The side-facing needle probe comprises miniaturized focusing optics consisting of no-core and GRIN fiber encased within a(More)
We present the smallest reported side-viewing needle probe for optical coherence tomography (OCT). Design, fabrication, optical characterization, and initial application of a 30-gauge (outer diameter 0.31 mm) needle probe are demonstrated. Extreme miniaturization is achieved by using a simple all-fiber probe design incorporating an angle-polished and(More)
Imaging of alveoli in situ has for the most part been infeasible due to the high resolution required to discern individual alveoli and limited access to alveoli beneath the lung surface. In this study, we present a novel technique to image alveoli using optical coherence tomography (OCT). We propose the use of OCT needle probes, where the distal imaging(More)
OBJECTIVE The purpose of this study was to evaluate a new imaging technique for the assessment of breast cancer tumor margins. The technique entails deployment of a high-resolution optical imaging needle under ultrasound guidance. Assessment was performed on fresh ex vivo tissue samples. CONCLUSION Use of the ultrasound-guided optical needle probe allowed(More)
We present a high-resolution three-dimensional position tracking method that allows an optical coherence tomography (OCT) needle probe to be scanned laterally by hand, providing the high degree of flexibility and freedom required in clinical usage. The method is based on a magnetic tracking system, which is augmented by cross-correlation-based resampling(More)
We present a high-optical-quality imaging needle for optical coherence tomography (OCT) that achieves sensitivity and resolution comparable to conventional free-space OCT sample arms. The side-viewing needle design utilizes total internal reflection from an angle-polished fiber tip, encased in a glass microcapillary. Fusion of the capillary to the fiber(More)
To the best of our knowledge, we present the first needle probe for combined optical coherence tomography (OCT), and fluorescence imaging. The probe uses double-clad fiber (DCF) that guides the OCT signal and fluorescence excitation light in the core and collects and guides the returning fluorescence in the large-diameter multimode inner cladding. It is(More)
We have developed an extremely miniaturized optical coherence tomography (OCT) needle probe (outer diameter 310 µm) with high sensitivity (108 dB) to enable minimally invasive imaging of cellular structure deep within skeletal muscle. Three-dimensional volumetric images were acquired from ex vivo mouse tissue, examining both healthy and pathological(More)
Endoscopic imaging using optical coherence tomography (OCT) has been demonstrated as clinically useful in the assessment of human airways. These airways have a complex 3D structure, bending, tapering and bifurcating. Previously published 3D OCT reconstructions have not accounted for changes in the orientation and trajectory of the endoscopic probe as it(More)