The Savannah River National Laboratory (SRNL) Weather Information and Display System was used to provide meteorological and atmospheric modeling/consequence assessment support to state and local agencies after the collision of two Norfolk Southern freight trains on the morning of January 6, 2005. This collision resulted in the release of several toxic(More)
Between 22 December and 25 December 1991, approximately 570 L of tritiated water was released from the K Reactor at the Savannah River Site. Analyses of river flow rates and measured tritium concentrations showed that approximately 210 TBq of tritium had been released from the reactor and was being transported down the Savannah River. Elevated tritium(More)