A major challenge since the invention of implantable devices has been a reliable and long-term stable transcutaneous communication. In the case of prosthetic limbs, existing neuromuscular interfaces have been unable to address this challenge and provide direct and intuitive neural control. Although prosthetic hardware and decoding algorithms are readily(More)
Processing and pattern recognition of myoelectric signals have been at the core of prosthetic control research in the last decade. Although most studies agree on reporting the accuracy of predicting predefined movements, there is a significant amount of study-dependent variables that make high-resolution inter-study comparison practically impossible. As an(More)
Supplementary article data Open Access-This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. A Zone B 6-month: films with remodeling (films graded) C 1-year: films with remodeling (films graded)(More)
The control of robotic prostheses based on pattern recognition algorithms is a widely studied subject that has shown promising results in acute experiments. The long-term implementation of this technology, however, has not yet been achieved due to practical issues that can be mainly attributed to the use of surface electrodes and their highly environmental(More)
BACKGROUND The concept of osseointegration involves direct contact between titanium implant and bone. This transcutaneous prosthetic system for amputees is intended to assure stable long-term fixation. Most metal transcutaneous implants have failed, primarily owing to infection. QUESTIONS/PURPOSES We determined the frequency and describe the presentation(More)
Falling represents a health risk for lower limb amputees fitted with an osseointegrated fixation mainly because of the potential damage to the fixation. The purpose of this study was to characterize a real forward fall that occurred inadvertently to a transfemoral amputee fitted with an osseointegrated fixation while attending a gait measurement session to(More)
This study directly measured the load acting on the abutment of the osseointegrated implant system of transfemoral amputees during level walking, and studied the variability of the load within and among amputees. Twelve active transfemoral amputees (age: 54 +/- 12 years, mass: 84.3 +/- 16.3 kg, height: 17.8 +/- 0.10 m) fitted with an osseointegrated implant(More)
BACKGROUND Osseointegrated percutaneous implants provide direct anchorage of the limb prosthesis to the residual limb. These implants have been used for the rehabilitation of transhumeral amputees in Sweden since 1995 using a two-stage surgical approach with a 6-month interval between the stages, but results on implant survival, adverse events, and(More)
Cuff electrodes have been widely used chronically in different clinical applications. This neural interface has been dominantly used for nerve stimulation while interfering noise is the major issue when employed for recording purposes. Advancements have been made in rejecting extra-neural interference by using continuous ring contacts in tripolar(More)
This study aimed at presenting the intra-tester reliability of the static load bearing exercises (LBEs) performed by individuals with transfemoral amputation (TFA) fitted with an osseointegrated implant to stimulate the bone remodeling process. There is a need for a better understanding of the implementation of these exercises particularly the reliability.(More)