PURPOSE To quantify the differences in setup errors measured with the cone-beam computed tomography (CBCT) and electronic portal image devices (EPID) in breast cancer patients. METHODS AND MATERIALS Repeat CBCT scan were acquired for routine offline setup verification in 20 breast cancer patients. During the CBCT imaging fractions, EPID images of the(More)
In this study, we present an analytical approach for optimizing the leaf design of a multi-leaf collimator (MLC) in a linear accelerator. Because leaf designs vary between vendors, our goal is to characterize and quantify the effects of different compromises which have to be made between performance parameters. Subsequently, an optimal leaf design for an(More)
PURPOSE To quantify the interfraction position variability of the excision cavity (EC) and to compare the rib and breast surface as surrogates for the cavity. Additionally, we sought to determine the required margin for on-line, off-line and no correction protocols in external beam radiotherapy. METHODS AND MATERIALS A total of 20 patients were studied(More)
PURPOSE To determine the use of surgical clips as a surrogate for localization of the excision cavity and to quantify the stability of the clips' positions during the course of external beam radiotherapy for breast cancer patients, using cone beam computed tomography (CBCT) scans. METHODS AND MATERIALS Twenty-one breast cancer patients with surgical clips(More)
PURPOSE To quantify the geometrical uncertainties for the heart during radiotherapy treatment of left-sided breast cancer patients and to determine and validate planning organ at risk volume (PRV) margins. METHODS AND MATERIALS Twenty-two patients treated in supine position in 28 fractions with regularly acquired cone-beam computed tomography (CBCT) scans(More)
In this study, we present the design for an alternative MLC system that allows high precision shaping of large fields. The MLC system consists of three layers of two opposing leaf banks. The layers are rotated 60 degrees relative to each other. The leaves in each bank have a standard width of 1 cm projected at the isocentre. Because of the symmetry of the(More)
In this study, we present a sequencer for delivering step-and-shoot IMRT using a six-bank multi-leaf system. Such a system was proposed earlier and combines a high-resolution field-shaping ability with a large field size. It consists of three layers of two opposing leaf banks with 1 cm leaves. The layers are rotated relative to each other at 60 degrees . A(More)
In this study, we quantify the impact of linac/MLC design parameters on IMRT treatment plans. The investigated parameters were leaf width in the MLC, leaf transmission, related to the thickness of the leaves, and penumbra related primarily to the source size. Seven head-and-neck patients with stage T1-T3N0-N2cM0 oropharyngeal cancer were studied. For each(More)