• Publications
  • Influence
Chromatographic Separations of Stereoisomers
Introduction. Stereoisomer Separations by Gas Chromatography. Stereoisomer Separations by High-Performance Liquid Chromatography. Stereoisomer Separations by Other Chro-matographic Techniques. Index.
Gas chromatographic resolution of enantiomeric amphetamines and related amines. I. Structural effects on some diastereomer separations.
  • R. W. Souter
  • Chemistry, Medicine
  • Journal of chromatography
  • 1 May 1975
Eight structurally related enantiomeric primary amines including several amphetamines were resolved as distereomers by gas chromatography. Optically active acylated amino acid chlorides were reactedExpand
Chromatographic resolution of enantiomers selective review.
Recent research has produced a notable increase in knowledge useful for chromatographic enantiomer resolution. Some major advances have emerged in the understanding of asymmetric solute-solventExpand
Direct gas chromatographic resolution of enantiomers on optically active mesophases : II. Effects of stationary phase structure on selectivity
Abstract The direct gas chromatographic resolution of enantiomers on optically active mesophases has been achieved using mesomorphic chiral carbonyl-bis-(amino acid esters). The resolving power ofExpand
Gas chromatographic quantitation of residual impurities in raw material matrixes
Abstract To quantitate accurately impurities such as crystallization solvents, isomers, or other residual substances in chemical raw materials, the effect of the matrix on those residuals must beExpand
Quantitative gas chromatographic analysis on support-coated open tubular capillary columns
Gas chromatographic methodology has been developed for quantitative analysis of samples of o-, m-, and p-ethylphenols. Samples are dissolved in a dichloromethane solution of the internal standard,Expand
Carbon-13 and proton magnetic resonance studies of some carbonyl-bis-(amino acid esters)
A number of carbonyl-bis-(amino acid esters) have been examined by proton and carbon-13 nuclear magnetic resonance techniques. All but one of the compounds were synthesized with two chiral centers ofExpand
Gas chromatographic resolution of enantiomeric amphetamines and related amines. II. Effects of cyclic structures on diastereomer and enantiomer resolution.
  • R. W. Souter
  • Chemistry, Medicine
  • Journal of chromatography
  • 26 November 1975
Proline and other cyclic amino acids were used as acylated acid chlorides for the resolution of enantiomers of amphentamine and related amines as diastereomers by gas chromatography. Variation ofExpand
...
1
2
3
...