• Publications
  • Influence
The IGEX Ge-76 neutrinoless double beta decay experiment: Prospects for next generation experiments
The International Germanium Experiment (IGEX) has analyzed 117 mole yr of 76Ge data from its isotopically enriched (86% 76Ge) germanium detectors. Applying pulse-shape discrimination (PSD) to theExpand
  • 282
  • 7
  • PDF
A Decommissioned LHC model magnet as an axion telescope
The 8.4 T, 10 m long transverse magnetic field of a twin aperture LHC bending magnet can be utilized as a macroscopic coherent solar axion-to-photon converter. Numerical calculations show that theExpand
  • 129
  • 5
  • PDF
Theoretical and experimental investigation of cosmogenic radioisotope production in germanium
Abstract Rates were calculated for the cosmic-ray-induced production of 3 H, 54 Mn, 57 Ni, 57,58 Co, 65,67 Ga, 65 Zn, and 68 Ge in natural germanium using two experimental neutron spectra from theExpand
  • 46
  • 4
Limits on cold dark matter candidates from an ultralow background germanium spectrometer
An ultralow background spectrometer is used as a detector of cold dark matter candidates from the halo of our galaxy Using a realistic model for the galactic halo, large regions of the mass-crossExpand
  • 190
  • 2
Neutrinoless double-{beta} decay of {sup 76}Ge: First results from the International Germanium Experiment (IGEX) with six isotopically enriched detectors
The International Germanium Experiment (IGEX) has six HPGe detectors, isotopically enriched to 86{percent} in {sup 76}Ge, containing approximately 90 active moles of {sup 76}Ge. Three detectors of 2Expand
  • 108
  • 2
Comment on "Evidence for Neutrinoless Double Beta Decay"
We comment on the recent claim for the experimental observation of neutrinoless double-beta decay. We discuss several limitations in the analysis provided in that paper and conclude that there is noExpand
  • 172
  • 2
  • PDF
Search for Neutrinoless Double-β Decay in ^{76}Ge with the Majorana Demonstrator.
The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-β decay in ^{76}Ge. The Majorana Demonstrator comprises 44.1 kg of Ge detectors (29.7 kgExpand
  • 61
  • 2
  • PDF
Pulse-shape discrimination in the IGEX experiment
Abstract The IGEX experiment has been operating enriched germanium detectors in the Canfranc Underground Laboratory (Spain) in a search for the neutrinoless double decay of 76 Ge . The implementationExpand
  • 36
  • 2
  • PDF
...
1
2
3
4
5
...