The long-term aim of the work introduced here is to investigate the influence of off-axis aberrations on human vision, especially for subjects with a large central scotoma. The latter use their peripheral vision in spite of its poor off-axis optical quality, and a correction of the off-axis aberrations might be of great assistance. The eccentric fixation(More)
Zernike polynomials and their associated coefficients are commonly used to quantify the wavefront aberrations of the eye. When the aberrations of different eyes, pupil sizes, or corrections are compared or averaged, it is important that the Zernike coefficients have been calculated for the correct size, position, orientation, and shape of the pupil. We(More)
Retinal sampling poses a fundamental limit to resolution acuity in the periphery. However, reduced image quality from optical aberrations may also influence peripheral resolution. In this study, we investigate the impact of different degrees of optical correction on acuity in the periphery. We used an adaptive optics system to measure and modify the(More)
PURPOSE Peripheral optical corrections are often thought to give few visual benefits beyond improved detection acuity. However, patients with central visual field loss seem to benefit from peripheral correction, and animal studies suggest a role for peripheral vision in the development of myopia. This study was conducted to bridge this gap by systematically(More)
PURPOSE To compare the subjective visual and objective optical performance of 2 aspherical intraocular lenses (IOLs), the Akreos Adapt Advanced Optics (AO) (Bausch & Lomb, Inc.) and the Tecnis Z9000 (Advanced Medical Optics, Inc.). SETTING Four university hospitals in Sweden. METHODS This study comprised 80 patients, 20 each from 4 university hospital(More)
We present a population study of peripheral wavefront aberrations in large off-axis angles in terms of Zernike coefficients. A laboratory Hartmann-Shack sensor was used to assess the aberrations in 0 degrees, 20 degrees, and 30 degrees in the nasal visual field of 43 normal eyes. The elliptical pupil meant that the quantification could be done in different(More)
PURPOSE Animal studies suggest that the periphery of the eye plays a major role in emmetropization. It is also known that human myopes tend to have relative peripheral hyperopia compared to the foveal refraction. This study investigated peripheral sensitivity to defocus in human subjects, specifically whether myopes are less sensitive to negative than to(More)
Measuring the contrast sensitivity function (CSF) in the periphery of the eye is complicated. The lengthy measurement time precludes all but the most determined subjects. The aim of this study was to implement and evaluate a faster routine based on the quick CSF method (qCSF) but adapted to work in the periphery. Additionally, normative data is presented on(More)
PURPOSE When performing perimetry, refracting subjects with central visual field loss, and in emmetropization studies, it is important to accurately measure peripheral refractive errors. Traditional methods for foveal refraction often give uncertain results in eccentric angles as a result of the large aberrations and the reduced retinal function. The aim of(More)
In a clinical setting, emphasis is given to foveal visual function, and tests generally only utilize static stimuli. In this study, we measured static (SVA) and dynamic visual acuity (DVA) in the central and peripheral visual field on healthy, young emmetropic subjects using stationary and drifting Gabor patches. There were no differences between SVA and(More)