A flow analysis (FA) system with spectrophotometric detection for Al determination in hemodialysis solutions was developed. The method was based on the reaction of Al with eriochrome cyanine R (ECR). The complex formed associated with cetyltrimethylammonium bromide (CTAB)--a cationic surfactant, which showed enough sensitivity to execute the direct analyte(More)
Electrothermal atomic absorption spectrophotometry of Al in a tungsten coil atomizer was evaluated and applied for its determination in hemodialysis fluid. The system was mounted on a Varian Spectra AA-40 spectrophotometer with continuum background correction and all measurements, in peak height absorbance, were done at 309.3 nm. The purge gas was a mixture(More)
In this work the polyphenol oxidase (PPO) was the main component of a biosensor for adrenaline determination. The activity of this enzyme was measured in several vegetables. Banana (Musa sp.) extracts presented better results with 974 UA (units of activity). The biosensor was constructed with a polyethylene tube (0.8 mm i.d.) filled with: carbon paste(More)
Oxidized carbon nanotubes were covered with layers of bovine serum albumin to result in so-called restricted-access carbon nanotubes (RACNTs). This material can extract Pb(2+) ions directly from untreated human blood serum while excluding all the serum proteins. The RACNTs have a protein exclusion capacity of almost 100% and a maximum Pb(2+) adsorption(More)
An autosampler/injector commutator for flow injection analysis (FIA) was constructed with electronic components of used equipments. The apparatus is controlled by commercially available multifunctional interface (PCL711B) connected to a personal computer, and the software was written in Visual Basic language. The system was applied to water analysis and it(More)
Many metals are toxic in human organism, as is the case of cadmium and lead. Therefore, the metal levels in food need to be controlled. In coffee, metals may present risks when they are extracted from the powder to be consumed as beverage. A flow injection analysis (FIA) system is proposed, with atomic absorption detection, to metal adsorption studies in(More)
In the present work, all steps of the sulfate reduction procedures, such as reduction, distillation and sulfate determination were joined in only one FIA system. The formed sulfide was on-line determined by employ the Fisher reaction. The proposed method presented a LOD of 1.00 μg L(-1) and a LOQ of 3.33 μg L(-1), well lower than the most commonly used(More)
In this work a spectrophotometric flow injection analysis system for streptomycin determination in veterinary samples, is being proposed. The method is based on streptomycin alkaline hydrolysis that forms guanidine, followed by the reaction with Fe(II). The colored product has absorption peak at 520 nm. To evaluate and optimize the system parameters,(More)
This paper describes selenium determination based on Se(0) preconcentration in the imprinted polymer (synthesized with 2.25mmol SeO2, 4-vinylpyridine and 1-vinylimidazole) with subsequent detection on-line in HG-FAAS. During the synthesis, SeO2 is reduced to Se (0). Therefore, there are no MIP neither IIP in the present work, thus we denominated: AIP, i.e.,(More)
In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes(More)