BACKGROUND The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that among high-risk patients with aortic stenosis, the 1-year survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical replacement. However, longer-term follow-up is necessary to determine whether TAVR has prolonged benefits. METHODS At 25(More)
Rats entrained to a 7 A.M.:7 P.M. lighting cycle had one eye patched and then were placed in either constant light or in a 2 A.M.:2 P.M. lighting cycle. In both cases, the patched eyes maintained the original pattern of rod outer segment (ROS) disc shedding, whereas the open eyes responded to the ambient lighting conditions. When the optic nerves were(More)
Rats raised from birth on a 7 A.M.:7 P.M. light cycle exhibited a circadian burst of shedding 1 1/2 hr after the scheduled onset of light. This rhythmic event persisted even after the animals had been placed in total darkness for up to 2 weeks. When animals were placed in constant light (LL) for more than 24 hr, the shedding peak was abolished. A period of(More)
BACKGROUND Intravascular ultrasound (IVUS) can assess stent geometry more accurately than angiography. Several studies have demonstrated that the degree of stent expansion as measured by IVUS directly correlated to clinical outcome. However, it is unclear if routine ultrasound guidance of stent implantation improves clinical outcome as compared with(More)
BACKGROUND Although several early trials indicate treatment of restenosis with radiation therapy is safe and effective, the long-term impact of this new technology has been questioned. The objective of this report is to document angiographic and clinical outcome 3 years after treatment of restenotic stented coronary arteries with catheter-based (192)Ir. (More)
BACKGROUND The optimal level of platelet inhibition with a glycoprotein (GP) IIb/IIIa antagonist necessary to minimize thrombotic complications in patients undergoing a percutaneous coronary intervention (PCI) is currently unknown. METHODS AND RESULTS Five hundred patients undergoing a PCI with the planned use of a GP IIb/IIIa inhibitor had platelet(More)
  • S G Ellis, M Savage, +7 authors C Walker
  • 1992
BACKGROUND Several metallic intracoronary stents are currently undergoing preliminary evaluation to ascertain potential benefit as means to reduce the 30-40% incidence of restenosis after balloon angioplasty. METHODS AND RESULTS To determine the incidence and correlates of restenosis after placement of Palmaz-Schatz stents in native coronary arteries in(More)
Diurnal patterns of retinal outer segment shedding and phagocytosis by the pigment epithelium were examined in pinealectomized, superior-cervical-ganglionectomized, and sham-operated rats. Phagocytosis was quantitatively similar in all groups. Sharp increases in the number of large phagosomes were observed soon after lights were turned on in the tree sets(More)
BACKGROUND Sirolimus-coated stents are a promising new therapy for restenosis. We treated a select group of patients at especially high risk for restenosis with oral sirolimus. METHODS AND RESULTS Patients were treated with an oral sirolimus-loading dose of 6 mg after coronary angioplasty, followed by 2 mg/d for 4 weeks. Serum electrolytes, lipid profile,(More)
BACKGROUND Observed rates of restenosis after drug-eluting stenting are low (<10%). Identification of a reliable and powerful angiographic end point will be useful in future trials. METHODS AND RESULTS Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and(More)