The purpose of this study was to evaluate the applicability of virtual endoscopy (VE) in the region of the nose and paranasal sinuses on the basis of volume-rendered spiral CT data. Forty-five patients underwent a low-dose spiral CT of the sinuses. The data were transferred to a workstation running software for volume rendering (EasyVision, Philips Medical(More)
BACKGROUND In order to investigate whether 1-mm thin slices and multiplanar reconstructions (MPRs) of multi-detector computed tomography (CT) datasets interpreted in addition to isotropic 5-mm thick slices in one session improve the detection of peritoneal carcinomatosis. METHODS The abdominal CT datasets of 44 patients with histologically proven tumors(More)
Sixty-four-slice CT typified the dramatic race in technical development in radiology. Featuring high spatial resolution with 0.5-mm thin slices and 0.3-second gantry revolution times, it has become state-of-the-art technology in CT imaging shortly after its clinical introduction. Three-dimensional tube modulation together with adaptive x-ray shutters led to(More)
The objective of this study was to evaluate the diagnostic yield of multislice CT using a radiation dose equivalent to that of conventional abdominal x-ray (KUB). One hundred forty-two patients were prospectively examined with ultrasound and a radically dose-reduced CT protocol (120 kV, 6.9 eff. mAs). Number and size of calculi, presence of urinary(More)
PURPOSE To compare the interobserver variability of the unidimensional diameter and volume measurements of pulmonary nodules in an intrascan and interscan analysis using semi-automated segmentation software on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT) data. MATERIALS AND METHODS In 33 patients with pulmonary nodules, two(More)
PURPOSE To compare the low-contrast detectability and image quality of computed tomography (CT) at different radiation dose levels reconstructed with iterative reconstruction (IR) and filtered back projection (FBP). MATERIALS AND METHODS A custom liver phantom with 12 simulated hypoattenuating tumors (diameters of 5, 10, 15, and 20 mm; tumor-to-liver(More)
PURPOSE To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). MATERIALS AND METHODS Multi-slice computed tomography (MSCT) data sets of 26 patients (13 male and 13(More)
PURPOSE The purpose of this study was to evaluate the performance of electron beam tomography (EBT) in the dynamic and quantitative assessment of tracheal collapse in tracheomalacia. METHOD Eight patients with suspected tracheomalacia were evaluated by EBT, and the results were correlated with both clinical symptoms and bronchoscopy. To validate this(More)
BACKGROUND Multislice computed tomography (CT) and magnetic resonance imaging (MRI) are the main candidates for noninvasive coronary angiography; however, multislice CT, unlike MRI, exposes patients to radiation and an iodinated intravenous contrast agent. OBJECTIVE To compare the diagnostic accuracy of multislice CT and MRI for noninvasive detection of(More)
We sought to determine the feasibility and image quality of 320-slice volume computed tomography (CT) angiography for the evaluation of patients with acute chest pain. Thirty consecutive patients (11 female, 19 male, mean age 63.2 +/- 14.2 years) with noncritical, acute chest pain underwent 320-slice CT using a protocol consisting of a nonspiral, nongated(More)