Electromyography readings (EMGs) from quadriceps of fifteen subjects were recorded during whole body vibration treatment at different frequencies (10-50 Hz). Additional electrodes were placed on the patella to monitor the occurrence of motion artifact, triaxial accelerometers were placed onto quadriceps to monitor motion. Signal spectra revealed sharp peaks(More)
OBJECTIVE We present a new, low power EEG recording system with an ultra-high input impedance that enables the use of long-lasting, passive dry electrodes. It incorporates Bluetooth wireless connectivity and is designed to be suitable for long-term monitoring during daily activities. METHODS The new EEG system is compared to a standard and clinically(More)
We present a new, low-power electrocardiogram (ECG) recording system with an ultra-high input impedance that enables the use of long-lasting, dry electrodes. The system incorporates a low-power Bluetooth module for wireless connectivity and is designed to be suitable for long-term monitoring during daily activities. The new system using dry electrodes was(More)
Diagnosis of low back pain and other degenerative spinal pathologies can be extremely difficult and, so far, there are not accepted standards. In general, such pathologies are associated with alteration of mechanical properties of spine and, in particular, with the instability of spinal motion. Intervertebral kinematics can be a valuable, objective method(More)
The aim of this study is to highlight the relationship between muscle motion, generated by whole body vibration, and the correspondent electromyographic (EMG) activity and to suggest a new method to customize the stimulation frequency. Simultaneous recordings of EMG and tri-axial accelerations of quadriceps rectus femoris from fifteen subjects undergoing(More)
Cost reduction has become the primary theme of healthcare reforms globally. More providers are moving towards remote patient monitoring, which reduces the length of hospital stays and frees up their physicians and nurses for acute cases and helps them to tackle staff shortages. Physiological sensors are commonly used in many human specialties e.g.(More)
Concise indexes related to variability of foetal heart rate (FHR) are usually utilised for foetal monitoring; they enrich information provided by cardiotocography (CTG). Most attention is paid to the short term variability (STV), which relates to activity and reaction of autonomic nervous control of foetal heart. There is not a unique method to compute(More)
Anterior knee pain (AKP) is a common pathological condition, particularly among young people and athletes, associated to an abnormal motion of the patella during the bending of the knee and possibly dependent on a muscular or structural imbalance. A lack of synergy in the quadriceps muscles results in a dynamic misalignment of the patella, which in turn(More)
Cardiotocography is the most diffused prenatal diagnostic technique in clinical routine. The simultaneous recording of foetal heart rate (FHR) and uterine contractions (UC) provides useful information about foetal well-being during pregnancy and labour. However, foetal electronic monitoring interpretation still lacks reproducibility and objectivity. New(More)