• Publications
  • Influence
Definition of the margin of major coronary artery bifurcations during radiotherapy with electrocardiograph-gated 4D-CT.
PURPOSE The aim was to measure the cardiac motion-induced displacements of major coronary artery bifurcations utilizing electrocardiography (ECG)-gated four-dimensional computed tomography (4D-CT)Expand
Quantification of heart, pericardium, and left ventricular myocardium movements during the cardiac cycle for thoracic tumor radiotherapy
Purpose The purpose of this study was to quantify variations in the heart, pericardium, and left ventricular myocardium (LVM) caused by cardiac movement using the breath-hold technique. Patients andExpand
Back-n white neutron facility for nuclear data measurements at CSNS
Back-streaming neutrons through the incoming proton channel at the spallation target station of China Spallation Neutron Source (CSNS) has been exploited as a white neutron beam line (so-calledExpand
Quantification of variation in dose–volume parameters for the heart, pericardium and left ventricular myocardium during thoracic tumor radiotherapy
Abstract Cardiac activity can induce dose–volume evaluation errors for cardiac structures. The purpose of this study was to quantify the variation in dose–volume parameters for the heart, pericardiumExpand
Impact of deformable image registration on dose accumulation applied electrocardiograph-gated 4DCT in the heart and left ventricular myocardium during esophageal cancer radiotherapy
BackgroundThe deformable image registration (DIR) technique has the potential to realize the dose accumulation during radiotherapy. This study will analyze the feasibility of evaluating dose-volumeExpand
Erratum to: Neutron energy spectrum measurement of the Back-n white neutron source at CSNS
In the original article, there were some errors in the list of authors and affiliations. Their correct version is given in this erratum.
The heterogeneous CTV-PTV margins should be given for different parts of tumors during tomotherapy
Objective The purpose of this study was to evaluate CTV-PTV margins of tumors for tomotherapy. Methods Setup errors were analyzed for 151 patients receiving helical tomotherapy treatment. 53 patientsExpand
T0 Fan-out for Back-n White Neutron Facility at CSNS
the main physics goal for Back-n white neutron facility at China Spallation Neutron Source (CSNS) is to measure nuclear data. The energy of neutrons is one of the most important parameters forExpand
Analysis of the evaluation errors of dose-volume parameters for left ventricular myocardium in esophageal cancer radiotherapy
Objective To evaluate the dynamic variation of the dose-volume parameters of the left ventricular myocardium following heart beat in radiotherapy for esophageal cancer. Methods The leftExpand
...
1
2
3
...