To evaluate the factors influencing flow information displayed by the power operating mode, color Doppler flow mapping was used to image the flow in an in vitro left heart pulse duplicator system. The effect of changing one instrument setting, such as pulse repetition frequency, color filter and frame rate while keeping all other instrumental settings(More)
BACKGROUND The purpose of our study was to validate the ability of real-time 3-dimensional echocardiography (RT3D) to measure cardiac volume. METHODS We studied 25 patients with various cardiac disorders who had a regular heart rhythm and a good precordial echocardiographic window. Each patient underwent complete transthoracic echocardiography (TTE),(More)
Tricuspid regurgitation severity was assessed preoperatively with Doppler color flow mapping and these assessments were compared with surgical findings in 90 patients undergoing mitral or aortic valve replacement, or both. Group I (n = 52) required tricuspid valve annuloplasty because tricuspid regurgitation was judged intraoperatively to be severe; in(More)
Contrast-enhanced 2-dimensional echocardiography without color Doppler did not result in complete filling of the left ventricular cavity in 21 patients studied. However, contrast-enhanced color Doppler was very effective and provided complete opacification of the left ventricular cavity in 20 of these 21 patients.
Doppler color flow mapping and color-guided conventional Doppler studies were performed on 119 patients with 126 prosthetic valves (mitral alone in 60, aortic alone in 52 and both mitral and aortic in 7 patients) within 2 weeks of the catheterization study or surgery, or both. The mean pressure gradients derived by color-guided continuous wave Doppler(More)
The commercially manufactured contrast agents, Echovist and Albunex, were compared with sonicated conventional agents, indocyanine green, 29% renografin-60, 0.9% normal saline and 25% mannitol in their ability to enhance color Doppler flow signals. In a pneumatically regulated pulsatile flow system, a glycerine, saline (0.9%) and sand (5 microns particle(More)
We evaluated the clinical applicability of a prototype tomographic transesophageal echocardiographic (TEE) system, which not only provides conventional TEE images but also three-dimensional tissue reconstruction and four-dimensional display capabilities. The probe was used in 16 patients in the echocardiographic laboratory, intensive care unit, and the(More)
The aim of the study was to compare the accuracy of multiplane transesophageal echocardiography (TEE) with the more conventional biplane technique in the direct assessment of aortic valve area in patients with aortic stenosis. Short-axis images of the aortic valve adequate for measuring aortic valve area were obtained in all 81 patients studied by(More)