This paper reports on the results of a neutron trial performance test sponsored by the European Commission and organised by EURADOS. As anticipated, neutron dosimetry results were very dependent on the dosemeter type and the dose calculation algorithm. Fast neutron fields were generally well measured, but particular problems were noted in the determination(More)
Following the publication of the EU Council Directive 96/29, EURADOS coordinated two working groups (WGs) for promoting the process of harmonisation on individual monitoring of occupationally exposed persons in Europe. An overview of the major findings of the second WG is presented. Information on the technical and quality standards and on the accreditation(More)
The current situation amongst Member States is that there are widely differing national requirements for dosimetric services and for dosemeter performance. It is clear that with the free movement of workers within the European Union (EU) and the requirements for individual dosimetry given in Council Directive 96/29 EURATOM, a degree of harmonisation of(More)
A large number of standards are available for radiation protection and individual monitoring purposes. They are published by various organisations, international and national. Moreover, the increasing policy of "Quality" applied to individual monitoring requires the implementation of standards on Quality Assurance (QA) both in technical and management(More)
The purpose of the European Commission technical recommendations (TR) for monitoring individuals occupationally exposed to external radiation is to provide guidance on those aspects of the implementation of the European Union Parliament and Council Directives directly related to individual monitoring of external radiation, and to encourage harmonisation(More)
According to ICRP 60, the radiation weighting factor for photon radiation is set equal to one, irrespective of photon energy and dose rate. However, it is well known that the relative biological effectiveness is not constant for all photon energies and also depends on the dose rate. If these dependencies are to be considered, both the photon energy and the(More)
The International Electrotechnical Commission (IEC) develops new standards for radiation protection dosemeters which follow a new concept. They are much more flexible in detail, but still ensure the same measurement quality. They are, for example, no longer specific for the detector type, but rather specific for the measurement task, e.g. for individual(More)
For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is not always possible to achieve this,(More)
For the purpose of radiation protection, ICRU Report 57/ICRP Publication 74 provides a list of monoenergetic conversion coefficients to be used with, among others, photon reference fields generated with X-ray tubes. A comprehensive definition of these photon reference fields can be found in international standard ISO 4037; however, it lacks thorough(More)
This article presents the evolution of the International Electrotechnical Commission (IEC) and the European standards for individual monitoring of ionising radiation issued, respectively, from the committees IEC/Sub Committee 45B and European Committee for Electro-technical Standardization/Technical Committee 45B 'Radiation protection instrumentation'.(More)