BACKGROUND Patients with advanced heart failure have improved survival rates and quality of life when treated with implanted pulsatile-flow left ventricular assist devices as compared with medical therapy. New continuous-flow devices are smaller and may be more durable than the pulsatile-flow devices. METHODS In this randomized trial, we enrolled patients(More)
BACKGROUND The use of left ventricular assist devices is an accepted therapy for patients with refractory heart failure, but current pulsatile volume-displacement devices have limitations (including large pump size and limited long-term mechanical durability) that have reduced widespread adoption of this technology. Continuous-flow pumps are newer types of(More)
OBJECTIVES This study sought to evaluate the use of a continuous-flow rotary left ventricular assist device (LVAD) as a bridge to heart transplantation. BACKGROUND LVAD therapy is an established treatment modality for patients with advanced heart failure. Pulsatile LVADs have limitations in design precluding their use for extended support. Continuous-flow(More)
BACKGROUND Implantable left ventricular assist devices have benefited patients with end-stage heart failure as a bridge to cardiac transplantation, but their long-term use for the purpose of enhancing survival and the quality of life has not been evaluated. METHODS We randomly assigned 129 patients with end-stage heart failure who were ineligible for(More)
BACKGROUND Contemporary ventricular assist device therapy results in a high rate of successful heart transplantation but is associated with bleeding, infections, and other complications. Further reductions in pump size, centrifugal design, and intrapericardial positioning may reduce complications and improve outcomes. METHODS AND RESULTS We studied a(More)
BACKGROUND We assessed the transmyocardial laser revascularization (TMLR) as sole therapy in patients with symptomatic coronary artery disease refractory to interventional or medical treatment. METHODS AND RESULTS Thirty-one patients were evaluated with positron emission tomography (PET), dobutamine echocardiography, 201Tl single-photon emission computed(More)
BACKGROUND The HeartMate II (Thoratec, Pleasanton, CA) is an effective bridge to transplantation (BTT) but requires anti-coagulation with warfarin and aspirin. We evaluated the risk of thromboembolism and hemorrhage related to the degree of anti-coagulation as reflected by the international normalized ratio (INR). METHODS INRs were measured monthly for 6(More)
BACKGROUND Previous studies suggest that the failing heart reactivates fetal genes and reverts to a fetal pattern of energy substrate metabolism. We tested this hypothesis by examining metabolic gene expression profiles in the fetal, nonfailing, and failing human heart. METHODS AND RESULTS Human left ventricular tissue (apex) was obtained from 9 fetal, 10(More)
OBJECTIVE The Levitronix CentriMag (Levitronix LLC, Waltham, Mass) ventricular assist system is designed for temporary left, right, or biventricular support. Advantages include ease of use, excellent reliability, and low thrombosis risk,. which may allow wider application of short-term support and improved outcomes in patients with cardiogenic shock. This(More)
We are investigating a new technique for myocardial revascularization in which an 800 W carbon dioxide laser is used to drill 1 mm diameter channels into a beating heart after left thoracotomy. Clotting occludes the channels on the subepicardium, and in the long-term setting, blood from the left ventricular cavity flows through these channels to perfuse the(More)