PURPOSE To reduce radiation dose from abdominal computed tomography (CT) without degradation of low-contrast detectability by using a technique with low tube voltage (90 kV). MATERIALS AND METHODS The institutional review board approved the participation of the radiologists in the observer performance test, and informed consent was obtained from all(More)
PURPOSE The purpose of this study was to reduce the radiation exposure of the eye lens in high resolution computed tomography (HRCT) of the temporal bone using an experimental phantom. MATERIALS AND METHODS The HRCT image that was used for analysis was obtained by changing parameters including effective-mAs (E-mAs), distance coverage, and height of object(More)
In this study, we evaluated the performance of a three-dimensional (3D) dose verification system, COMPASS version 3, which has a dedicated beam models and dose calculation engine. It was possible to reconstruct the 3D dose distributions in patient anatomy based on the measured fluence using the MatriXX 2D array. The COMPASS system was compared with Monte(More)
Using glass rod dosimeters we investigated the radiation dose to the operator performing interventional procedures in 43 patients with the aid of a monoplane flat detector-based angiography system. During the procedures we recorded the number of radiographic frames and the radiographic conditions. After treatment we recorded the fluoroscopy time and the(More)
In this study, we evaluated the dosimetric performance of the three-dimensional (3D) dose verification system, COMPASS version 3 (IBA Dosimetry, GmbH, Germany). The COMPASS has the function of a dedicated beam modeling and dose calculation. It is able to reconstruct 3D dose distributions on patient CT images, using the incident fluence from a linear(More)
The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using(More)
In this study, we evaluated various image guided radiation therapy (IGRT) systems regarding accuracy and patient throughput for conventional radiation therapy. We compared between 2D-2D match (the collation by 2 X-rays directions), cone beam computed tomography (CBCT), and ExacTrac X-Ray system using phantom for CLINAC iX and Synergy. All systems were able(More)
Our purpose in this study was to evaluate the performance of four-dimensional computed tomography (4D-CBCT) and to optimize the acquisition parameters. We evaluated the relationship between the acquisition parameters of 4D-CBCT and the accuracy of the target motion trajectory using a dynamic thorax phantom. The target motion was created three dimensionally(More)
The dosimetric properties between various 2D array detectors were compared and were evaluated with regard to the accuracy in absolute dose and dose distributions for clinical treatment fields. We used to check the dose accuracy: 2D array detectors; MapCHECK (Sun Nuclear), EPID (Varian Medical Systems), EPID-based dosimetry (EPIDose, Sun Nuclear), COMPASS(More)
PURPOSE We developed a quality assurance (QA) phantom to enable easy confirmation of radiation source output measurements of a high dose rate (192)Ir intracavitary brachytherapy unit in gynecology. The purpose of this study was to evaluate the feasibility of daily checks using the QA phantom. METHODS AND MATERIALS The QA phantom was designed with tough(More)