• Publications
  • Influence
Landsat-8 Operational Land Imager Radiometric Calibration and Stability
The Landsat-8 Operational Land Imager (OLI) was radiometrically calibrated prior to launch in terms of spectral radiance, using an integrating sphere source traceable to National Institute ofExpand
  • 126
  • 6
Radiometric Cross Calibration of Landsat 8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+)
This study evaluates the radiometric consistency between Landsat-8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+) using cross calibration techniques. Two approachesExpand
  • 102
  • 6
Absolute Calibration of Optical Satellite Sensors Using Libya 4 Pseudo Invariant Calibration Site
The objective of this paper is to report the improvements in an empirical absolute calibration model developed at South Dakota State University using Libya 4 (+28.55°, +23.39°) pseudo invariantExpand
  • 60
  • 4
Applications of Spectral Band Adjustment Factors (SBAF) for Cross-Calibration
To monitor land surface processes over a wide range of temporal and spatial scales, it is critical to have coordinated observations of the Earth's surface acquired from multiple spaceborne imagingExpand
  • 97
  • 3
Assessment of Spectral, Misregistration, and Spatial Uncertainties Inherent in the Cross-Calibration Study
Cross-calibration of satellite sensors permits the quantitative comparison of measurements obtained from different Earth Observing (EO) systems. Cross-calibration studies usually use simultaneous orExpand
  • 27
  • 3
The Ground-Based Absolute Radiometric Calibration of Landsat 8 OLI
This paper presents the vicarious calibration results of Landsat 8 OLI that were obtained using the reflectance-based approach at test sites in Nevada, California, Arizona, and South Dakota, USA.Expand
  • 81
  • 2
Absolute Radiometric Calibration of Landsat Using a Pseudo Invariant Calibration Site
  • D. Helder, K. Thome, +4 authors T. Choi
  • Mathematics, Computer Science
  • IEEE Transactions on Geoscience and Remote…
  • 19 February 2013
Pseudo invariant calibration sites (PICS) have been used for on-orbit radiometric trending of optical satellite systems for more than 15 years. This approach to vicarious calibration has demonstratedExpand
  • 69
  • 1
Impact of Terra MODIS Collection 6 on long-term trending comparisons with Landsat 7 ETM+ reflective solar bands
Recently, the Moderate Resolution Imaging Spectroradiometer (MODIS) Characterization Support Team (MCST) has worked closely with the science team members to make significant improvements in bothExpand
  • 13
  • 1
CONTINUOUS CALIBRATION IMPROVEMENT: LANDSAT 5 THROUGH LANDSAT 8.
Launched in February 2013, the Operational Land Imager (OLI) on-board Landsat 8 continues to perform exceedingly well and provides high science quality data globally. Several design enhancements haveExpand
  • 25
  • 1
Radiometric Non-Uniformity Characterization and Correction of Landsat 8 OLI Using Earth Imagery-Based Techniques
Landsat 8 is the first satellite in the Landsat mission to acquire spectral imagery of the Earth using pushbroom sensor instruments. As a result, there are almost 70,000 unique detectors on theExpand
  • 13
  • 1