Natalie Urwyler

Learn More
BACKGROUND This prospective, randomized, controlled trial compares the performance of the pediatric i-gel (Intersurgical Ltd., Wokingham, United Kingdom) with the Ambu AuraOnce laryngeal mask (Ambu A/S, Ballerup, Denmark) in anesthetized and ventilated children. METHODS With ethics committee approval and written informed consent, the authors included 208(More)
BACKGROUND The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube(More)
BACKGROUND Many guidelines exist on how to treat patients with multiple injuries correctly in an accident and emergency setting. The aim of the present work was to find out how well patients are treated focusing on trauma induced coagulopathy (TIC), and what anaesthetists involved in trauma care think about their own experiences with TIC. METHODS In a(More)
BACKGROUND The single-use supraglottic airway devices LMA-Supreme (LMA-S; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) and i-gel (Intersurgical Ltd, Wokingham, Berkshire, United Kingdom) have a second tube for gastric tube insertion. Only the LMA-S has an inflatable cuff. They have the same clinical indications and might be useful for difficult(More)
OBJECT Resection of lesions close to the primary motor cortex (M1) and the corticospinal tract (CST) is generally regarded as high-risk surgery due to reported rates of postoperative severe deficits of up to 50%. The authors' objective was to determine the feasibility and safety of low-threshold motor mapping and its efficacy for increasing the extent of(More)
BACKGROUND The i-gel™ supraglottic airway device has been studied in randomized controlled studies, but it has not been evaluated in a large prospective patient cohort. Therefore, we performed this prospective multicentre observational study to evaluate success rates, airway leak pressure, risk factors for i-gel failure, and adverse events. METHODS With(More)
BACKGROUND The i-gel™ is a single-use supraglottic airway device (SAD) that allows fibreoptic-guided tracheal intubation through the device. Until now, no prospective data for this procedure are available. Therefore, in a prospective randomized controlled trial, we evaluated fibreoptic-guided tracheal intubation with a standard Rüsch™ PVC tracheal tube (TT)(More)
There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in(More)
BACKGROUND Helicopter emergency medical services (HEMSs) have become a standard element of modern prehospital emergency medicine. This study determines the percentage of injured HEMS patients whose injuries were correctly recognized by HEMS physicians. METHODS A retrospective level III evidence prognostic study using data from the largest Swiss HEMS, REGA(More)
BACKGROUND Two major difficulties arise when taking blood samples in children: the challenge of venous access and the comparatively large amount of blood required. OBJECTIVE To assess the value of point-of-care prothrombin time testing in paediatric intensive care patients. We evaluated two point-of-care devices, CoaguChek XS Plus and CoaLine, assessing(More)