This paper presents the design of a non-intrusive system to measure ultra-low water content in crude oil. The system is based on a capacitance to phase angle conversion method. Water content is measured with a capacitance sensor comprising two semi-cylindrical electrodes mounted on the outer side of a glass tube. The presence of water induces a capacitance(More)
In crude oil extraction and processing, measurement of water content plays vital role. Several methods are available to measure water content in crude oil but most of them are laborious and for offline detection. For an accurate online measurement of water content in crude oil, a novel interface circuit is proposed by using differential capacitive sensor(More)