Quantitative 124I PET imaging is challenging as 124I has a complex decay scheme. In this study the performance of a Philips Gemini dual GS PET/CT system was optimized and assessed for 124I. The energy window giving the maximum noise equivalent count rate (NECR) and NEMA 2001-NU2 image quality were measured. The activity concentration (AC) accuracy of images(More)
BACKGROUND AND PURPOSE The Normal Tissue Complication Probability (NTCP) for rectum is usually defined for late rectal bleeding. This study calculates NTCP parameter values for additional rectal toxicity endpoints observed in clinical practise. MATERIALS AND METHODS 388 patients from the multicentre MRC-RT01 prostate conformal radiotherapy trial (ISRCTN(More)
BACKGROUND AND PURPOSE As techniques for radiotherapy delivery have developed, increasingly accurate localisation of disease is demanded. Functional imaging, particularly PET and its fusion with anatomical modalities, such as PET/CT, promises to improve detection and characterisation of disease. This study evaluated the impact of (18)FDG-PET/CT on(More)
Many studies have reported dosimetric characteristics of amorphous silicon electronic portal imaging devices (EPIDs). Some studies ascribed a non-linear signal to gain ghosting and image lag. Other reports, however, state the effect is negligible. This study compares the signal-to-monitor unit (MU) ratio for three different brands of EPID systems. The(More)
PURPOSE Radical radiotherapy for prostate cancer is effective but dose limited because of the proximity of normal tissues. Comprehensive dose-volume analysis of the incidence of clinically relevant late rectal toxicities could indicate how the dose to the rectum should be constrained. Previous emphasis has been on constraining the mid-to-high dose range(More)
An evaluation of the capabilities of a commercially available camera-based electronic portal imaging system for intensity-modulated radiotherapy verification is presented. Two modifications to the system are demonstrated which use a novel method to tag each image acquired with the delivered dose measured by the linac monitor chamber and reduce optical(More)
Many studies have been performed to assess correlations between measures derived from dose-volume histograms and late rectal toxicities for radiotherapy of prostate cancer. The purpose of this study was to quantify correlations between measures describing the shape and location of the dose distribution and different outcomes. The dose to the rectal wall was(More)
PURPOSE/OBJECTIVE To analyse outcome and toxicity of stereotactic body radiotherapy (SBRT) in pancreatic cancer (PDAC). MATERIAL/METHODS We systematically reviewed full reports on outcome and toxicity transforming prescription doses to equivalent doses of 2 Gy (EQD2) and biological equivalent doses (BED). Pearson product-moment correlation coefficient,(More)
The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been transformed by the implementation of(More)
BACKGROUND AND PURPOSE The study aimed to examine specific avoidance of functional lung (FL) defined by a single photon emission computerized tomography (SPECT) lung perfusion scan, using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3-DCRT) in patients with non-small cell lung cancer (NSCLC). MATERIALS AND METHODS(More)