BACKGROUND The accurate Monte Carlo simulation of a linac requires a detailed description of its geometry and the application of elaborate variance-reduction techniques for radiation transport. Both tasks entail a substantial coding effort and demand advanced knowledge of the intricacies of the Monte Carlo system being used. METHODS PRIMO, a new Monte(More)
In this work we present PENLINAC, a code package developed to facilitate the use of the Monte Carlo code PENELOPE for the simulation of therapeutic beams, including high-energy electrons, photons and 60Co beams. The code simplifies the creation of the treatment machine geometry, allowing the modeling of their components from elementary geometric bodies and(More)
PURPOSE Phase-space files for Monte Carlo simulation of the Varian TrueBeam beams have been made available by Varian. The aim of this study is to evaluate the accuracy of the distributed phase-space files for flattening filter free (FFF) beams, against experimental measurements from ten TrueBeam Linacs. METHODS The phase-space files have been used as(More)
A method based on a combination of the variance-reduction techniques of particle splitting and Russian roulette is presented. This method improves the efficiency of radiation transport through linear accelerator geometries simulated with the Monte Carlo method. The method named as 'splitting-roulette' was implemented on the Monte Carlo code [Formula: see(More)
PURPOSE The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters C1 and C2. The authors have(More)
The dosimetric parameters for characterization of a low-energy interstitial brachytherapy source (125)I are examined. In this work, the radial dose function, g(r), anisotropy function F(r,theta), and the absolute dose rate, Lambda, around (125)I seed model 6711 have been estimated by means of the PENELOPE Monte-Carlo (MC) simulation code. The results(More)
Monte Carlo simulation of linear accelerators (linacs) depends on the accurate geometrical description of the linac head. The geometry of the Varian TrueBeam linac is not available to researchers. Instead, the company distributes phase-space files of the flattening-filter-free (FFF) beams tallied at a plane located just upstream of the jaws. Yet, Monte(More)
BACKGROUND AND PURPOSE An anthropomorphic water filled polymethylmethacrylate (PMMA) phantom designed to serve as a Quality Assurance (QA) tool and a training aid in brachytherapy of gynaecological tumours is investigated and presented. Several dosimetric parameters associated with the dose rate calculation can be verified with the aid of this phantom such(More)
General-purpose radiation transport Monte Carlo codes have been used for estimation of the absorbed dose distribution in external photon and electron beam radiotherapy patients since several decades. Results obtained with these codes are usually more accurate than those provided by treatment planning systems based on non-stochastic methods. Traditionally,(More)
The use of brachytherapy sources in radiation oncology requires their proper calibration to guarantee the correctness of the dose delivered to the treatment volume of a patient. One of the elements to take into account in the dose calculation formalism is the non-uniformity of the photon fluence due to the beam divergence that causes a steep dose gradient(More)