The use of artificial bones in implant testing has become popular due to their low variability and ready availability. However, friction coefficients, which are critical to load transfer in uncemented implants, have rarely been compared between human and artificial bone, particularly for wet and dry conditions. In this study, the static and dynamic friction(More)
The interference press fit of a metallic one-piece acetabular cup employed for metal-on-metal hip resurfacing procedures was investigated experimentally under laboratory conditions in the present study, in particular regarding the cup deformation. Tests were carried out in cadavers as well as polyurethane foams of various grades with different elastic(More)
BACKGROUND A stable fixation between femoral head and endoprosthesis taper is necessary to prevent relative motions and corrosion at the taper junction. Although the importance of the component assembly has been recognised, no definitive instructions are available. The purpose of this study was to assess the influence of assembly force, assembly tool and(More)
The aim here was to define realistic load conditions for hip implants, based on in vivo contact force measurements, and to see whether current ISO standards indeed simulate real loads. The load scenarios obtained are based on in vivo hip contact forces measured in 4 patients during different activities and on activity records from 31 patients. The load(More)
Particulate wear debris can activate defence cells and osteoclasts at the bone-implant interface possibly leading to bone resorption and implant failure. Cellular responses and inflammatory effects have been reported for particulate hydroxyapatite (HA). However, the immunological effects of particulate beta-tricalciumphosphate (beta-TCP) have not been(More)
OBJECTIVES To examine the influence of in vivo hydrolysis on the physical properties of polyester grafts and their correlation to the period of implantation in the human body. MATERIALS AND METHODS Sixty-five explanted vascular grafts were obtained after 0-23 years of implantation due to suture aneurysms (18), occlusion (12), graft infection (12), failure(More)
BACKGROUND Robotic-assisted total hip replacement has become a common method of implantation, especially in Europe. It frequently has been postulated that robotic reaming would result in an improved clinical outcome due to the better fit of the prosthesis, but that has never been demonstrated in a prospective study, to our knowledge. The purpose of this(More)
Little knowledge about frequency and duration of daily activities in patients after total hip arthroplasty is available. Such information is required for the definition of realistic load collectives for pre-clinical testing of prostheses. It could also be helpful for the quantitative evaluation of surgery outcome with different prosthesis types. The purpose(More)
With rising demand on highly accurate acquisition of small motion the use of video-based motion capturing becomes more and more popular. However, the performance of these systems strongly depends on a variety of influencing factors. A method was developed in order to systematically assess accuracy and precision of motion capturing systems with regard to(More)
The deformation of metallic acetabular cups employed for metal-on-metal hip resurfacing procedures was considered theoretically using the finite element method in the present study, following on the experimental investigation reported in Part 1. Three representative cups, characterized by the cup wall thickness as thin, intermediate, and thick, were(More)