The aim of this study was to test a large sample of the latest coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in dual-source multidetector row CT (DSCT) in vitro and to provide a CT catalogue of currently used coronary artery stents. Twenty-nine different coronary(More)
Purpose. To test different peripheral arterial stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation and image noise in dual-source multidetector row CT (DSCT) in vitro. Methods and Materials. 22 stents (nitinol, steel, cobalt-alloy, tantalum, platinum alloy) were examined in a vessel phantom. All stents(More)
BACKGROUND Assesment of the coronary arteries after stent placement using coronary computed tomography angiography (CCTA) currently requires reconstruction of images with soft kernels for the assessment of atherosclerotic plaques and dedicated edge enhancing kernels for the evaluation of the stent lumen. PURPOSE To evaluate a two-dimensional filter tool(More)
Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid) stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy) were examined in a(More)
To evaluate the diagnostic potential of PET/MRI with [18F]FDG in comparison to PET/CT in patients with differentiated thyroid cancer suspected or known to have dedifferentiated. The study included 31 thyroidectomized and remnant-ablated patients who underwent a scheduled [18F]FDG PET/CT scan and were then enrolled for a PET/MRI scan of the neck and thorax.(More)
RATIONALE AND OBJECTIVES To evaluate the quality of stent lumen delineation using dual-source computed tomography (DSCT) in the standard-pitch mode (SP) as compared to the high-pitch mode (HP) in a phantom study. MATERIALS AND METHODS Forty different coronary stents placed in plastic tubes filled with contrast agent were imaged with a second generation(More)
OBJECTIVE Aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) is associated with a poor clinical outcome and its assessment therefore crucial. Quantification of AR by transthoracic echocardiography (TTE), however, remains challenging in this setting. The present study used quantitative flow measurement by cardiac MRI (CMR) with(More)
The purpose of this study was to determine whether [68Ga]DOTATATE PET/MRI with diffusion-weighted imaging (DWI) can replace or complement [18F]FDG PET/CT in patients with radioactive-iodine (RAI)-refractory differentiated thyroid cancer (DTC). The study population comprised 12 patients with elevated thyroglobulin and a negative RAI scan after thyroidectomy(More)
Background Extracorporeal membrane oxygenation (ECMO) and extracorporeal life support (ECLS) as respiratory and circulatory assist therapies are gaining in importance in the treatment of critically ill patients. Depending on the place of cannulation - veno-venous for ECMO and veno-arterial for ECLS - distinct changes in hemodynamics will occur. In this(More)