Matthew J. Hilt

Learn More
When only a single composition sensor is available for a multi-zone co-evaporation process, it can be difficult to determine the relative amount of material deposited in each zone. In this paper, a method of estimating the deposition-rate ratio between zones using small signal perturbation sequences is presented that exploits the exponential dependence of(More)