Marco Bordin

  • Citations Per Year
Learn More
PURPOSE To assess ocular surface status and tolerability after switching glaucoma patients from dorzolamide/timolol to brinzolamide/timolol fixed combination (FC). METHODS Six-month, multicenter, open-label, prospective study that switched 72 patients from dorzolamide/timolol to brinzolamide/timolol FC. Intraocular pressure (IOP), tear film break-up-time(More)
Purpose: To compare aqueous humor pH changes during femtosecond (FS) laser-assisted cataract surgery with conventional cataract surgery. Results: The mean pH was 6.53 ± 0.09 (range 6.42-6.70) and 7.42 ± 0.07 (range 7.28-7.48) in Groups 1 and 2, respectively. Differences between groups in this parameter were statistically significant (p < 0.001).(More)
PURPOSE To validate the Italian version of the Glaucoma Symptom Scale (GSS) Questionnaire and its symptoms and function subscales. METHODS This transversal validation study enrolled nonhospitalized patients with glaucoma, and a reference sample of patients without eye diseases. Eligible participants had to be cognitively able to respond to a health status(More)
INTRODUCTION Non-arteritic anterior ischemic optic neuropathy (NAION) is one of the most widespread visually disabling diseases in the middle-aged and elderly population. It typically presents as acute painless unilateral vision loss in patients over 50 years of age. The fellow eye of NAION patients is often sequentially affected. Involvement of the second(More)
The principle aim of the present work is the evaluation of the importance of the variable "depth" of needle insertion in the determination of acupuncture's therapeutic results. A randomized clinical trial carried out on 44 patients belonging to two groups of 22 each, suffering from shoulder myofascial pain: group A: superficial acupuncture; group B: deep(More)
The monitoring of diabetic patients by evaluating glycated protein levels is now widely accepted and performed. The microchromatographic version of the high performance liquid chromatography method is the technique most frequently used in clinical practice. The DCA 200 instrument (Bayer Diagnostics, Milan, Italy), based on an immunochemical technique, has(More)
The torsional angle was calculated goniometrically of 9 femurs and 2 tibio-peroneal groups, and then compared to the values obtained from CT scans of the corresponding bones. The results show how the methods adopted up to now have been inaccurate and have yielded only gross definitions of the axis of the femoral neck. As far as this feature is concerned, an(More)
  • 1