A literature review of electronic portal imaging for radiotherapy dosimetry.
Electronic portal imaging devices (EPIDs) have been the preferred tools for verification of patient positioning for radiotherapy in recent decades. Since EPID images contain dose information, manyExpand
  • 401
  • 18
  • PDF
Electron-vibrational coupling in the Fenna-Matthews-Olson complex of Prosthecochloris aestuarii determined by temperature dependent absorption and fluorescence line narrowing measurements
Fluorescence line-narrowing measurements at low temperature were performed on the Fenna−Matthews−Olson complex of Prosthecochloris aestuarii. Superimposed on the phonon wing, several vibronic bandsExpand
  • 137
  • 7
  • PDF
Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.
The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In thisExpand
  • 196
  • 6
3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry.
BACKGROUND AND PURPOSE To demonstrate the feasibility of back-projection portal dosimetry for accurate 3D dosimetric verification of volumetric-modulated arc therapy (VMAT), pre-treatment as well asExpand
  • 161
  • 6
A fast algorithm for gamma evaluation in 3D.
The gamma-evaluation method is a tool by which dose distributions can be compared in a quantitative manner combining dose-difference and distance-to-agreement criteria. Since its introduction, theExpand
  • 132
  • 4
Catching errors with in vivo EPID dosimetry.
The potential for detrimental incidents and the ever increasing complexity of patient treatments emphasize the need for accurate dosimetric verification in radiotherapy. For this reason, all curativeExpand
  • 53
  • 4
3D in vivo dose verification of entire hypo-fractionated IMRT treatments using an EPID and cone-beam CT.
As radiotherapy becomes more complicated, dose and geometry verification become more necessary. The aim of this study was to use back-projected EPID-based 3D in vivo dosimetry and cone-beam CT (CBCT)Expand
  • 80
  • 3
Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routineExpand
  • 83
  • 3
In aqua vivo EPID dosimetry.
PURPOSE At the Netherlands Cancer Institute--Antoni van Leeuwenhoek Hospital in vivo dosimetry using an electronic portal imaging device (EPID) has been implemented for almost all high-energy photonExpand
  • 51
  • 3
The quantitative relationship between structure and polarized spectroscopy in the FMO complex of Prosthecochloris aestuarii: refining experiments and simulations
New absorption, linear dichroism (LD) and circular dichroism (CD) measurements at low temperatures on the Fenna—Matthews—Olson complex from Prosthecochloris aestuarii are presented. Furthermore, theExpand
  • 79
  • 3
  • PDF
...