Is the Determination of Specific IgE against Components Using ISAC 112 a Reproducible Technique?
- R. Martínez-Aranguren, M. Lizaso, M. Sanz
- Medicine, BiologyPLoS ONE
- 6 February 2014
The allergen microarray immunoassay, ISAC 112, is a repeatable and reproducible in vitro diagnostic tool for determination of sIgE beyond the own laboratory.
Early skin testing is effective for diagnosis of hypersensitivity reactions occurring during anesthesia
- A. Lafuente, G. Javaloyes, G. Gastaminza
- MedicineAllergy. European Journal of Allergy and Clinical…
- 1 June 2013
Early allergological study is useful, could minimize false negatives, but should be considered as a complement to late skin tests.
Comparable actions of omalizumab on mast cells and basophils
- E. Serrano-Candelas, R. Martínez-Aranguren, M. Ferrer
- Medicine, BiologyClinical and Experimental Allergy
- 1 January 2016
Omalizumab is equally and rapidly effective against autoimmune and non‐autoimmune urticaria, suggesting the possible involvement of additional mechanisms of IgE.
Altered cardiac expression of peroxisome proliferator-activated receptor-isoforms in patients with hypertensive heart disease.
- M. J. Goikoetxea, J. Beaumont, J. Díez
- Medicine, BiologyCardiovascular Research
- 1 March 2006
Pru p 3 acts as a strong sensitizer for peanut allergy in Spain.
- G. Javaloyes, M. J. Goikoetxea, M. Ferrer
- MedicineJournal of Allergy and Clinical Immunology
- 1 December 2012
The usefulness of plasma histamine and different tryptase cut‐off points in the diagnosis of peranaesthetic hypersensitivity reactions
- F. Berroa, A. Lafuente, G. Gastaminza
- Medicine, BiologyClinical and Experimental Allergy
- 1 February 2014
Assessment of the diagnostic usefulness of plasma histamine and different cut‐off points of serum tryptase for anaesthetic hypersensitivity reactions found them to be useful in the diagnosis of these reactions.
Recommendations for the use of in vitro methods to detect specific immunoglobulin E: are they comparable?
- M. J. Goikoetxea, M. Sanz, J. Monteseirin Mateo
- BiologyJournal of investigational allergology & clinical…
- 2013
Differences between ImmunoCAP and ISAC microarray, 2 methods from the same manufacturer used to detect IgE to specific proteins (purified or recombinant) are analyzed and show that the IgE values obtained with Immuno CAP are not equivalent to the correspondingvalues obtained with the ISACmicroarray system.
Can component‐based microarray replace fluorescent enzimoimmunoassay in the diagnosis of grass and cypress pollen allergy?
- P. Cabrera-Freitag, M. J. Goikoetxea, M. Sanz
- MedicineClinical and Experimental Allergy
- 1 October 2011
This work has shown clear improvements in the diagnostic accuracy in pollinosis of the microarray ISAC of allergens, particularly in relation to the presence or absence of egg yolk in the blood of mice infected with E.coli.
In vivo and in vitro testing with rAni s 1 can facilitate diagnosis of Anisakis simplex allergy.
- R. Martínez-Aranguren, P. Gamboa, E. García-Lirio, J. Asturias, M. J. Goikoetxea, M. Sanz
- MedicineJournal of investigational allergology & clinical…
- 2014
BACKGROUND
Traditional diagnostic tests such as skin prick tests (SPT) and specific IgE (slgE) against whole Anisakis simplex extract have low specificity. Consequently, allergy to A simplex is…
Proteomic and Biological Analysis of an In Vitro Human Endothelial System in Response to Drug Anaphylaxis
- A. Yuste-Montalvo, S. Fernández-Bravo, V. Esteban
- Biology, MedicineFrontiers in Immunology
- 25 June 2021
New target proteins and relevant signaling pathways operating in the in vitro endothelial-serum system have been identified and the coagulation, fibrinolytic, contact and complement systems in human anaphylaxis are described.
...
...