• Publications
  • Influence
Technical Design Report EuroGammaS proposal for the ELI-NP Gamma beam System
The machine described in this document is an advanced Source of up to 20 MeV Gamma Rays based on Compton back-scattering, i.e. collision of an intense high power laser beam and a high brightnessExpand
  • 59
  • 10
  • PDF
Patient dose in full-field digital mammography: an Italian survey
The aim of this study was to compare performance and patient dose of full-field digital mammography units for clinical use. Measurements of linearity and automatic exposure control stability wereExpand
  • 38
  • 5
An ultrasound model to calculate the brain blood outflow through collateral vessels: a pilot study
BackgroundThe quantification of the flow returning from the head through the cervical veins and the collaterals of the internal jugular vein (IJV), is becoming of prominent interest in clinicalExpand
  • 51
  • 4
Guidelines on the standards for the training of specialised health professionals dealing with breast cancer.
According to EUSOMA position paper 'The requirements of a specialist breast unit', each breast unit should have a core team made up of health professionals who have undergone specialist training inExpand
  • 89
  • 2
  • PDF
Mammography with synchrotron radiation.
PURPOSE To determine the feasibility of using synchrotron radiation (SR) in diagnostic mammography. MATERIALS AND METHODS Monochromatic SR of x-ray beams of selected energies of 14-20 keV were usedExpand
  • 97
  • 2
Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography
Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, thatExpand
  • 41
  • 2
A new hemodynamic model for the study of cerebral venous outflow.
We developed a mathematical model of the cerebral venous outflow for the simulation of the average blood flows and pressures in the main drainage vessels of the brain. The main features of the modelExpand
  • 29
  • 2
  • PDF
Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography.
Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, thatExpand
  • 15
  • 2
Measurement of focal spot size in a 5.5 MeV linac
Abstract High energy X-ray beams allow to perform analysis on different materials and objects of relevant interest that cannot be investigated with conventional X-ray sources. A 5.5 MeV endpointExpand
  • 14
  • 2
Dual-energy tissue cancellation in mammography with quasi-monochromatic x-rays.
Dual-energy radiography has not evolved into a routine clinical examination yet due to intrinsic limitations of both dual-kVp imaging and single-exposure imaging with conventional x-ray sources. TheExpand
  • 144
  • 1
...
1
2
3
4
5
...