Radiation therapy accelerators require highly accurate dose deposition and the output must be monitored frequently and regularly. Ionization chambers are the primary tool for this control, but their size, their high voltage needed, and the correction needed for electrons make them unsuitable for use during patient treatment. We have developed a small(More)
Hadrontherapy treatments require a very high precision on the dose deposition ( 2.5% and 1-2mm) in order to keep the benefits of the precise ions’ ballistic. The largest uncertainty on the physical dose deposition is due to ion fragmentation. Up to now, the simulation codes are not able to reproduce the fragmentation process with the required precision. To(More)
We demonstrate that abundant quantities of short-lived beta unstable ions can be trapped in a novel transparent Paul trap and that their decay products can directly be detected in coincidence. Low energy 6He+ (807 ms half-life) ions were extracted from the SPIRAL source at GANIL, then decelerated, cooled, and bunched by means of the buffer gas cooling(More)
New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance than in classical radiotherapy in order to(More)
We report the results of test measurements aimed at determining the performances of (6)Li doped glass scintillators for the detection of ultra-cold neutrons. Four types of scintillators, GS1, GS3, GS10 and GS20, which differ by their (6)Li concentrations, have been tested. The signal to background separation is fully acceptable. The relative detection(More)
Proton CT (pCT) nowadays aims at improving hadron therapy treatment planning by mapping the relative stopping power (RSP) of materials with respect to water. The RSP depends mainly on the electron density of the materials. The main information used is the energy of the protons. However, during a pCT acquisition, the spatial and angular deviation of each(More)
The transport and cooling of noble gas singly-charged ion beams by means of a Radio Frequency Quadrupole Cooler Buncher (RFQCB) have been studied at the LIMBE low energy beam line of the GANIL facility. Ions as light as He have been cooled and stored before their extraction in bunches using H2 as buffer gas. Bunches characteristics have been studied as a(More)