To verify whether the treatment of brain oligometastases with whole-brain radiotherapy (WBRT) plus stereotactic radiotherapy (SRT) or surgical resection results in different outcomes. Files of patients affected by brain metastases submitted to surgical resection followed by WBRT (group A) or WBRT + SRT (group B) were retrospectively selected for this study.(More)
To assess survival, local control and toxicity using fractionated stereotactic conformal radiotherapy (FSCRT) boost and temozolomide in high-grade gliomas (HGGs). Patients affected by HGG, with a CTV1(clinical target volume, representing tumor bed ± residual tumor + a margin of 5 mm) ≤ 8 cm were enrolled into this phase II study. Radiotherapy (RT, total(More)
AIM To analyze the outcome of patients with brain oligometastases treated by radiosurgery (SRS) or fractionated stereotactic radiotherapy (FSRT) after whole-brain radiotherapy (WBRT). PATIENTS AND METHODS Overall survival (OS) and local control (LC) were evaluated in patients (patients) with 1-2 brain metastases. RESULTS Forty-seven patients were(More)
An amorphous silicon (a-Si) electronic portal imaging device (EPID) was implemented to perform transit in vivo dosimetry for dynamic conformal arc therapy (DCAT). A set of images was acquired for each arc irradiation using the EPID cine acquisition mode, that supplies a frame acquisition rate of one image every 1.66 s, with a monitor unit rate equal to 100(More)
A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoiding many of the disadvantages associated(More)
This work reports the results of the application of a practical method to determine the in vivo dose at the isocenter point, D(iso), of brain thorax and pelvic treatments using a transit signal S(t). The use of a stable detector for the measurement of the signal S(t) (obtained by the x-ray beam transmitted through the patient) reduces many of the(More)
A 2D array (PTW, type 10024), equipped with 729 vented plane parallel ion-chambers, has been calibrated as a detector for the in vivo comparison between measured and predicted portal doses for head-neck tumors. The comparison of absolute portal doses measured to ones predicted by a commercial treatment planning system within the field of view of the CT(More)
Three radiation detectors based on polycrystalline diamond films with different thickness and resistivity, obtained by microwave chemical vapor deposition, were tested to assess their suitability for relative dosimetry of photon and electron beams supplied by clinical linear accelerators. All samples showed a linear response as a function of the absorbed(More)
As all methods for in-vivo dosimetry require special efforts many physicists are often discouraged in verifying the middle dose in a patient along the beam central axis. This work reports a practical method for the determination of the middle dose value, D(m), on the central beam axis, using a signal S(t), obtained by a small thimble ion-chamber positioned(More)
The transit in vivo dosimetry performed by an electronic portal imaging device (EPID) is a very practical method to check error sources in radiotherapy. Recently, the present authors have developed an in vivo dosimetry method based on correlation functions, F (w, L), defined as the ratio between the transit signal, S t (w, L), by the EPID and the mid-plane(More)