PURPOSE To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG). SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular(More)
PURPOSE To compare visual acuity after bilateral implantation of 2 models of multifocal aspheric intraocular lenses (IOLs). SETTING Fernández-Vega Ophthalmological Institute, Oviedo, and University of Valencia, Valencia, Spain. METHODS Prospective study of patients who had bilateral implantation of an AcrySof ReSTOR SN6AD3 IOL (Group 1) or an Acri.LISA(More)
PURPOSE To assess the safety, efficacy, and predictability in eyes that had refractive lens exchange (RLE) with implantation of a spherical diffractive intraocular lens (IOL) after previous hyperopic laser in situ keratomileusis (LASIK). SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS This prospective study evaluated eyes that(More)
PURPOSE To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity,(More)
PURPOSE To compare visual acuity at different distances after bilateral implantation of 1 of 4 multifocal intraocular lenses (IOLs). SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS This study evaluated consecutive patients who had bilateral implantation of a spherical multifocal IOL with a +4.00 diopter (D) addition (add)(More)
PURPOSE To assess the safety, efficacy, stability, and predictability of collagen copolymer toric phakic intraocular lens (pIOL) implantation to correct myopia and astigmatism in eyes with keratoconus. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS This prospective study comprised keratoconic eyes that had implantation of a(More)
PURPOSE To evaluate distance, intermediate, and near vision after bifocal aspheric AcrySof ReSTOR SN6AD1 intraocular lens (IOL) implantation. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS Binocular distance best corrected visual acuity (BCVA) (4.0 m), best distance-corrected near (40.0 cm) and intermediate (70.0, 60.0, 50.0(More)
OBJECTIVE To evaluate the postoperative outcomes and intraoperative and postoperative complications of clear lens extraction (CLE) with posterior chamber intraocular lens (IOL) implantation in highly myopic eyes. DESIGN Retrospective case series. PARTICIPANTS One hundred seven patients (190 eyes) who had undergone CLE with posterior chamber IOL(More)
PURPOSE To assess the predictability, efficacy, safety, and stability of collagen copolymer toric phakic intraocular lens (pIOL) implantation to correct moderate to high myopic astigmatism. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS This study comprised eyes that had implantation of a toric Intraocular Collamer Lens for(More)
PURPOSE To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL). SETTING Private Clinic, Oviedo, Spain. METHODS Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual(More)