Lingqin Kong

Learn More
A method that remotely measures blood oxygen saturation through two cameras under regular lighting is proposed and experimentally demonstrated. Two narrow-band filters with their visible wavelength of 660nm and 520nm are mounted to two cameras respectively, which are then used to capture two photoplethysmographic (PPG) from the subject simultaneously. The(More)
A novel fiber reference optical readout method was proposed in the bi-material micro cantilever infrared imaging system, which consists of an infrared imaging channel, an optical readout channel and a fiber reference channel. The fiber reference channel is used to monitor the intensity fluctuation of the light source, and provide a signal to correct the(More)
In this paper, we compare the performance of radar and optical (camera based) techniques in detecting vital signs such as respiratory rate (RR), heart rate (HR), and blood oxygen saturation (SpO<sub>2</sub>). Specifically, we investigate the application of ultrawideband stepped-frequency continuous-wave radar and imaging photoplethysmography (iPPG)(More)
The structured light illumination method is applied in an optical readout uncooled infrared imaging system to improve the IR image quality. The unavoidable nonuniform distribution of the initial bending angles of the bimaterial cantilever pixels in the focal plane array (FPA) can be well compensated by this method. An ordinary projector is used to generate(More)
In this paper, we theoretically and experimentally demonstrate that the imaging speed of the optomechanical focal plane array infrared imaging system can be significantly improved by changing the pressure in the vacuum chamber. The decrease in the thermal time constant is attributed to the additional thermal conductance caused by air. The response time will(More)
In this paper, we develop an angles-centroids fitting (ACF) system and the centroid algorithm to calibrate the reverse Hartmann test (RHT) with sufficient precision. The essence of ACF calibration is to establish the relationship between ray angles and detector coordinates. Centroids computation is used to find correspondences between the rays of datum(More)
We report the experimental results to continuously tune the coherence length of a semiconductor laser using an optical feedback scheme. The coherence length can be controlled by adjusting the feedback strength when a semiconductor laser operates in a coherence collapse regime. Fine structures of the fringe visibility of the laser output show that the(More)
Wavefront coding (WFC) technology is adopted in the space optical system to resolve the problem of defocus caused by temperature difference or vibration of satellite motion. According to the theory of WFC, we calculate and optimize the phase mask parameter of the cubic phase mask plate, which is used in an on-axis three-mirror Cassegrain (TMC) telescope(More)
This paper presents a novel filtering method with a double triangular prism in an optical-readout thermal imaging system. First, the working principle of this system is described in detail, followed by the analysis of sensitivity. Then, infrared images of hands are obtained. On the basis of the analysis, it is concluded that this filtering method, whose(More)
  • 1