This paper deals with the dielectric barrier discharge (DBD) ion source composed of the outer cylindrical dielectric tube and the inner grounded metallic tube electrode. The sample gas is supplied through the inner ceramic tube. In this ion source, the DBD plasma is localized in the DBD tube so that the sample gases can be ionized just outside of the(More)
The probe electrospray ionization (PESI) is an ESI-based ionization technique that generates electrospray from the tip of a solid metal needle. In this work, mass spectra for the single-shot PESI were measured as a function of time for a mixture of several analytes with different surface activity values. It was found that the analytes were elecrosprayed in(More)
Probe electrospray ionization (PESI) is a modified version of the electrospray ionization (ESI), where the capillary for sampling and spraying is replaced by a solid needle. High tolerance to salts and direct ambient sampling are major advantages of PESI compared with conventional ESI. In this study, PESI-MS was used to monitor some biological and chemical(More)
We have demonstrated that, with simple pH adjustment, volatile drugs such as methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, and valproic acid could be analyzed rapidly from raw biofluid samples (e.g. urine and serum) without dilution, or extraction, using atmospheric pressure ionization. The ion source was a variant type(More)
Probe electrospray ionization (PESI) has recently been developed, in which the electrospray was generated from a solid needle instead of by using a capillary. In this paper, the characteristics of probe electrospray ionization were studied based on the measurement of spray current, optical microscopy, and PESI mass spectrometry. In the experiment, the solid(More)
Although being an atmospheric pressure ion source, electrospray ionization (ESI) has rarely been used directly for ambient imaging mass spectrometry because the sample has to be introduced as liquid solution through the capillary. Instead of capillary, probe electrospray ionization (PESI), which has been developed recently, uses a solid needle as the(More)
Recently, we have developed probe electrospray ionization (PESI) that uses a solid needle. In this system, the probe needle moves up and down along the vertical axis by a motor-driven system. At the highest position of the probe needle, electrospray is generated by applying a high voltage. In this study, we applied PESI directly to biological samples such(More)
Probe electrospray ionization (PESI) is a recently developed technique that uses a fine solid needle as a probe for sampling biological materials. In this study, we quantified the volume of liquid sample picked up by the solid needle with the tip diameter of approximately 700 nm and the apex angle of approximately 60 degrees. The amounts of low-viscosity(More)
Detergents are necessarily used for different extraction protocols of proteins from biological cells or tissues. After the extraction, elimination of detergent is necessary for the better performance of electrospray ionization mass spectrometry (ESI-MS). Elimination of detergents is laborious and time-consuming, and also sample loss may be unavoidable.(More)