Validation of two portable bioelectrical impedance analyses for the assessment of body composition in school age children
Background Bioelectrical impedance analysis (BIA) is a convenient and child-friendly method for longitudinal analysis of changes in body composition. However, most validation studies of BIA have beenExpand
  • 24
  • 2
The study of anthropometric estimates in the visceral fat of healthy individuals
BackgroundAbdominal visceral fat affects the metabolic processes, and is an important risk factor for morbidity and mortality. The purpose of the study was to develop a quick and accurate estimate inExpand
  • 18
  • 2
Bladder injection of "naked" hSlo/pcDNA3 ameliorates detrusor hyperactivity in obstructed rats in vivo.
The goal of these studies was to examine the potential utility of bladder instilled K+ channel gene therapy with hSlo cDNA (i.e., the maxi-K channel) to ameliorate bladder overactivity in a rat modelExpand
  • 61
  • 1
Predicting body composition using foot-to-foot bioelectrical impedance analysis in healthy Asian individuals
BackgroundThe objectives of this study were to develop a regression model for predicting fat-free mass (FFM) in a population of healthy Taiwanese individuals using standing foot-to-foot bioelectricalExpand
  • 18
  • 1
The novel application of artificial neural network on bioelectrical impedance analysis to assess the body composition in elderly
BackgroundThis study aims to improve accuracy of Bioelectrical Impedance Analysis (BIA) prediction equations for estimating fat free mass (FFM) of the elderly by using non-linear Back PropagationExpand
  • 11
  • 1
Comparison of Different Measurement Equations for Body Composition Estimation in Male Athletes
The purpose of this study was to compare the validity between three established prediction equations and our prediction equation referenced by DEXA (Dual-energy X-ray absorptiometry) on fat free massExpand
  • 3
  • 1
Alleviating effects of dehydration under no hyperthermia on the immunomodulatory response to the polysaccharide fraction from fu-ling (Poria cocos) in male collegiate wrestlers.
BACKGROUND It is well known that dehydration can impair bodily functions. To evaluate the impact of hydration status under ambient environmental temperature on the immune system, 25 male collegiateExpand
  • 8
Validity of Standing Posture Eight-electrode Bioelectrical Impedance to Estimate Body Composition in Taiwanese Elderly
Summary Background Standing eight-electrode bioelectrical impedance analysis, which can be used to estimate percentage body fat (BF%) and lean soft tissue (LST) in the whole body and different bodyExpand
  • 5
Cross-mode bioelectrical impedance analysis in a standing position for estimating fat-free mass validated against dual-energy x-ray absorptiometry.
Bioelectrical impedance analysis (BIA) is commonly used to assess body composition. Cross-mode (left hand to right foot, Z(CR)) BIA presumably uses the longest current path in the human body, whichExpand
  • 12
Discrepancies between leg-to-leg bioelectrical Impedance analysis and computerized tomography in abdominal visceral fat measurement
The aim of this study was to evaluate leg-to-leg bioelectrical impedance analysis (LBIA) using a four-contact electrode system for measuring abdominal visceral fat area (VFA). The present studyExpand
  • 4