This paper proposes an open computer language (OpenCL) parallel processing method to generate the elemental image arrays (EIAs) for hexagonal lens array from a three-dimensional (3D) object such as a volume data. Hexagonal lens array has a higher fill factor compared to the rectangular lens array case; however, each pixel of an elemental image should be(More)
We propose a 360 degree integral-floating display with an enhanced vertical viewing angle. The system projects two-dimensional elemental image arrays via a high-speed digital micromirror device projector and reconstructs them into 3D perspectives with a lens array. Double floating lenses relate initial 3D perspectives to the center of a vertically curved(More)
In the breast-cancer image detection device field, remarkable advancements have been made in the breast cancer detection method using microwave radiation that satisfies the conditions required by Institute of Medicine (IOM). This paper is for embodying the microwave analysis breast tumor detection system that can analyze the permittivity and the(More)
A resolution-enhanced integral imaging microscope that uses lens array shifting is proposed in this study. The lens shift method maintains the same field of view of the reconstructed orthographic view images with increased spatial density. In this study, multiple sets of the elemental images were captured with horizontal and vertical shifts of the micro(More)
A viewing angle enhanced integral imaging display using two elemental image masks is proposed. In our new method, rays emitted from the elemental images are directed by two masks into corresponding lenses. Due to the elemental image guiding of the masks, the number of elemental images for each integrated image point is increased, enhancing the viewing(More)
Due to the limitations of micro lens arrays and camera sensors, images on display devices through the integral imaging microscope systems have been suffering for a low-resolution. In this paper, a resolution-enhanced orthographic-view image display method for integral imaging microscopy is proposed and demonstrated. Iterative intermediate-view(More)
In an integral imaging display, the computer-generated integral imaging method has been widely used to create the elemental images from a given three-dimensional object data. Long processing time, however, has been problematic especially when the three-dimensional object data set or the number of the elemental lenses are large. In this paper, we propose an(More)
A real-time interactive orthographic-view image display of integral imaging (II) microscopy that includes the generation of intermediate-view elemental images (IVEIs) for resolution enhancement is proposed. Unlike the conventional II microscopes, parallel processing through a graphics processing unit is required for real-time display that generates the(More)
1College of Electrical and Computer Engineering, Chungbuk National University, 410 SungBong-ro, Heungduk-gu, Cheongju-si, Chungbuk 361-763, South Korea 2Department of Computer Education and IIE, Chungbuk National University, 410 SungBong-ro, Heungduk-gu, Cheongju-si, Chungbuk 361-763, South Korea 3Department of Thoracic & Cardiovascular Surgery, Chungbuk(More)
A depth-of-field enhancement method for integral imaging microscopy system using a spatial multiplexing structure consisting of a beamsplitter with dual video channels and micro lens arrays is proposed. A computational integral imaging reconstruction algorithm generates two sets of depth-sliced images for the acquired depth information of the captured(More)