Dual-photon absorptiometry using153Gd (44 and 100 keV) was used to measure the bone mineral content (BMC) of the trunk and of the total body (TBBM) in 7 volunteers with no overt bone disease. These values were compared to those obtained with partial-body neutron activation of calcium (trunk Ca). The trunk Ca seemed to represent best a 60 × 30 cm area; the(More)
In vivo neutron activation analysis has been used to measure bone mineral content in the central skeleton where osteoporotic fractures occur. To be of diagnostic value, the results must be normalized for body size. From data obtained from 74 healthy children and adults up to 55 years of age, we have found that the calcium in the central skeleton is(More)
The Radiology Department at the University of Arizona has been operating a teleradiology program for almost 2 years. The goal of this project was to characterize the types of cases reviewed, to assess radiologists’ satisfaction with the program, and to examine case turnaround times. On average, about 50 teleradiology cases are interpreted each month.(More)
Long-term anticonvulsant drug therapy may lead to abnormalities of calcium metabolism resulting in osteomalacia. The prevalence and severity of altered calcium metabolism was studied in an adult outpatient population of persons with epilepsy receiving anticonvulsant therapy for a minimum of 2 years. Assessment of calcium metabolism was based on serum(More)
A mehtod of measuring body nitrogen by neutron capture gamma analysis is described. The neutron flux is provided by four collimated 5 Ci Pu-Be sources, placed to give a bilateral irradiation of the subject. The 10-83 MeV thermal neutron capture gamma rays from 14N are detected by two heavily shielded 5 in X 4 in NaI(Tl) detectors. Results indicate a(More)
The design and construction of a hospital clinical facility for in vivo prompt gamma neutron activation analysis for total body nitrogen (TBN) measurement is described. The use of 252Cf neutron sources gives a better signal-to-background ratio compared with 238Pu-Be sources of equal strength, thus yielding better reproducibility of measurements. By(More)
In 1998 we surveyed our radiologists on teleradiology satisfaction. Results were generally positive. In 2002 we experienced a sevenfold case increase in teleradiology volume. The present study surveyed the radiologists again. The hypothesis was that, with increased case volume and radiologist experience with the system, ratings would increase. Image quality(More)