Learn More
Purity determination of pure organic substance is essential for the establishment of traceability to SI units. A mass balance method was employed to determine the purity of theophylline certified reference materials (CRM), compared with high performance liquid chromatography (HPLC) and differential scanning calorimetry (DSC). In the approach of the mass(More)
A sensitive fluorimetric method for determination of phytic acid in human urine samples was described. The method was based on a fluorimetric replacement reaction, in which the added phytic acid replaced the Cu2+ ion from Cu2+-gelatin complex, liberating the fluorescent gelatin molecule. The fluorescence of the solution was accordingly recovered(More)
A simple and sensitive method was developed for the simultaneous separation and determination of trace earthy-musty compounds including geosmin, 2-methylisoborneol, 2-isobutyl-3-methoxypyrazine, 2-isopropyl-3-methoxypyrazine, 2,3,4-trichloroanisole, 2,4,6-trichloroanisole, and 2,3,6-trichloroanisole in water samples. This method combined headspace(More)
An accurate method combining high performance liquid chromatography (HPLC) with diode array detection (DAD) and ion-trap time-of-flight mass spectrometry (IT-TOF/MS) was developed for simultaneous identification and quantification of 34 water-soluble synthetic dyes in foodstuff. Fragmentation patterns of synthetic dyes were proposed based on IT-TOF/MS. The(More)
The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of(More)
Certified reference materials (CRMs) of water content are widely used in the calibration and validation of Karl Fischer coulometry and volumetry. In this study, the water content of the water saturated 1-octanol (WSO) CRM was certified by Karl Fischer coulometry, volumetry and quantitative nuclear magnetic resonance (Q NMR). The water content recovery by(More)
A variable inclined swirl system (VISS) was developed to generate in-cylider inclined swirl air motion in a four-valve SI engine, the in-cylinder inclined swirl characteristics generated by VISS were studied in steady flow rig, and the effect of inclined swirl characteristics on cyclic variation of combustion pressure were analyzed with combustion analyzer(More)
  • 1