The Challenge on Liver Ultrasound Tracking (CLUST) was held in conjunction with the MICCAI 2014 conference to enable direct comparison of tracking methods for this application. This paper reports the outcome of this challenge, including setup, methods, results and experiences. The database included 54 2D and 3D sequences of the liver of healthy volunteers(More)
Modern techniques as ion beam therapy or 4D imaging require precise target position information. However, target motion particularly in the abdomen due to respiration or patient movement is still a challenge and demands methods that detect and compensate this motion. Ultrasound represents a non-invasive, dose-free and model-independent alternative to(More)
PURPOSE The use of motion mitigation techniques such as tracking and gating in particle therapy requires real-time knowledge of tumor position with millimeter precision. The aim of this phantom-based study was to evaluate the option of diagnostic ultrasound (US) imaging (sonography) as real-time motion detection method for scanned heavy ion beam irradiation(More)
Scanned ion pencil beams carry a low-dose envelope which can extend up to several centimeters from the individual beam central axis. Depending on the energy and species of the beam, this halo consists mainly of secondary particles produced by nuclear interactions in the target or of particles undergoing multiple Coulomb scattering in the beam line(More)
Target motion, particularly in the abdomen, due to respiration or patient movement is still a challenge in many diagnostic and therapeutic processes. Hence, methods to detect and compensate this motion are required. Diagnostic ultrasound (US) represents a non-invasive and dose-free alternative to fluoroscopy, providing more information about internal target(More)
In der modernen Strahlentherapie kann die Dosis mit einer Genauigkeit von 1–2 mm appliziert werden, sofern die Position der Zielstruktur genau bekannt ist. Liegt diese Zielstruktur (der Tumor) jedoch in der Lunge oder im Abdomen, können u. a. die Atmung oder die Peristaltik zu einer substanziellen Bewegung des Zielvolumens führen. Verschiedene Methoden zur(More)
Automated three-dimensional breast ultrasound (ABUS) is a valuable adjunct to x-ray mammography for breast cancer screening of women with dense breasts. High image quality is essential for proper diagnostics and computer-aided detection. We propose an automated image quality assessment system for ABUS images that detects artifacts at the time of(More)