High Levels of Residue within Polymeric Hollow Fiber Membranes Used for Blood Oxygenation
TLDR
This work found large amounts of leachable oils associated with several commercial HFMs, i.e., as much as 2.5–7.5 weight percent, and found that s-ATRP coatings were uniform and continuous across the hollow fibers. Expand
Long Term Blood Oxygenation Membranes
OF DISSERTATION LONG TERM BLOOD OXYGENATION MEMBRANES Hollow fiber membranes are widely used in blood oxygenators to remove carbon dioxide and add oxygen during cardiopulmonary bypass operations.Expand