BACKGROUND An artificial pancreas (AP) that can be worn at home from dinner to waking up in the morning might be safe and efficient for first routine use in patients with type 1 diabetes. We assessed the effect on glucose control with use of an AP during the evening and night plus patient-managed sensor-augmented pump therapy (SAP) during the day, versus 24(More)
AIMS To test in an outpatient setting the safety and efficacy of continuous subcutaneous insulin infusion (CSII) driven by a modular model predictive control (MMPC) algorithm informed by continuous glucose monitoring (CGM) measurement. METHODS 13 patients affected by type 1 diabetes participated to a non-randomized outpatient 42-h experiment that included(More)
OBJECTIVE After testing of a wearable artificial pancreas (AP) during evening and night (E/N-AP) under free-living conditions in patients with type 1 diabetes (T1D), we investigated AP during day and night (D/N-AP) for 1 month. RESEARCH DESIGN AND METHODS Twenty adult patients with T1D who completed a previous randomized crossover study comparing 2-month(More)
AIMS To assess the accuracy and reliability of the two most widely used continuous glucose monitoring (CGM) systems. METHODS We studied the Dexcom®G4 Platinum (DG4P; Dexcom, San Diego, CA, USA) and Medtronic Paradigm Veo Enlite system (ENL; Medtronic, Northridge, CA, USA) CGM systems, in 24 patients with type 1 diabetes. The CGM systems were tested during(More)
OBJECTIVE It is known that continuous glucose monitoring (CGM) systems can lower mean glucose compared with episodic self-monitoring of blood glucose. Implantable CGM systems may provide additional benefits. RESEARCH DESIGN AND METHODS We studied the Eversense (Senseonics Inc.) implantable CGM sensor in 71 participants aged 18 years and older with type 1(More)
BACKGROUND Using the standard venous reference for the evaluation of continuous glucose monitoring (CGM) systems could possibly negatively affect measured CGM accuracy since CGM are generally calibrated with capillary glucose and venous and capillary glucose concentrations differ. We therefore aimed to quantify the effect of using capillary versus venous(More)
The development of accurate and easy-to-use continuous glucose monitoring (CGM) improved diabetes treatment by providing additional temporal information on glycemia and glucose trends to patient and physician. Although CGM enables users to lower their average glucose level without an increased incidence of hypoglycemia, this comes at the price of additional(More)
AIM To assess the impact on fear of hypoglycaemia and treatment satisfaction with an artificial pancreas system used for 2 consecutive months, as well as participant acceptance of the artificial pancreas system. METHODS In a randomized crossover trial patient-related outcomes associated with an evening-and-night artificial pancreas and sensor-augmented(More)