Jonathan S. Maltz

Learn More
OBJECTIVE Abnormal cutaneous vasodilatory responses to the iontophoresis of vasodilators were previously observed in Alzheimer's disease (AD). We sought to replicate these observations and further identify peripheral vascular components of AD pathology. METHODS Methacholine chloride (MCh), acetylcholine chloride (ACh), and sodium nitroprusside (SNP) were(More)
PURPOSE In current image guided pretreatment patient position adjustment methods, image registration is used to determine alignment parameters. Since most positioning hardware lacks the full six degrees of freedom (DOF), accuracy is compromised. The authors show that such compromises are often unnecessary when one models the planned treatment beams as part(More)
Impairment of arterial endothelial function is an early event in atherosclerosis and correlates with the major risk factors for cardiovascular disease. The most widely employed non-invasive measure of endothelial function involves brachial artery (BA) diameter measurement using ultrasound imaging before and after several minutes of blood flow occlusion. The(More)
The authors present the design and simulation of an imaging system that employs a compact multiple source x-ray tube to produce a tomosynthesis image from a set of projections obtained at a single tube position. The electron sources within the tube are realized using cold cathode carbon nanotube technology. The primary intended application is(More)
We present an algorithm of reduced computational cost which is able to estimate kinetic model parameters directly from dynamic ECT sinograms made up of temporally inconsistent projections. The algorithm exploits the extreme degree of parameter redundancy inherent in linear combinations of the exponential functions which represent the modes of first-order(More)
The very nature of nuclear medicine, the visual representation of injected radiopharmaceuticals, implies imaging of dynamic processes such as the uptake and wash-out of radiotracers from body organs. For years, nuclear medicine has been touted as the modality of choice for evaluating function in health and disease. This evaluation is greatly enhanced using(More)
Quantitative reconstruction of cone beam X-ray computed tomography (CT) datasets requires accurate modeling of scatter, beam-hardening, beam profile, and detector response. Typically, commercial imaging systems use fast empirical corrections that are designed to reduce visible artifacts due to incomplete modeling of the image formation process. In contrast,(More)
The RKHS-based optimal image interpolation method, presented by Chen and de Figueiredo (1993), is applied to scattered potential field measurements. The RKHS which admits only interpolants consistent with Laplace's equation is defined and its kernel, derived. The algorithm is compared to bicubic spline interpolation, and is found to yield vastly superior(More)
We describe a focused beam-stop array (BSA) for the measurement of object scatter in imaging systems that utilize x-ray beams in the megavoltage (MV) energy range. The BSA consists of 64 doubly truncated tungsten cone elements of 0.5 cm maximum diameter that are arranged in a regular array on an acrylic slab. The BSA is placed in the accessory tray of a(More)
Sums of decaying real exponentials (SDREs) are frequently used in models of time-varying processes. First-order compartmental models are widely employed to describe mass transit in chemical and biological systems. In these models the evolution of compartment concentration versus time is represented as the convolution of an input function with an SDRE. In(More)