• Publications
  • Influence
X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in mice.
Using X-ray fluorescent computed tomography (XFCT), the in vivo and ex vivo cerebral distribution of a stable-iodine-labeled cerebral perfusion agent, iodoamphetamine analog (127I-IMP), has been
The functional hepatic volume assessed by99mTc-GSA hepatic scintigraphy
TLDR
The results indicate that the hepaticVolume ratio is proportional to the severity of hepatic dysfunction, and suggest that the functional hepatic volume measured with99mTc-GSA faithfully reflects the functioning hepatocyte mass.
Sheet-beam geometry for in vivo fluorescent x-ray computed tomography: proof-of-concept experiment in molecular imaging.
TLDR
The feasibility of a fluorescent x-ray computed tomography method using an array of detectors with an incident sheet beam is proved by imaging an acrylic phantom and a normal mouse brain using a preliminary imaging system with monochromatic synchrotron x rays.
Interferometer-based Phase-contrast X-ray Computed Tomography of Colon Cancer Specimens: Comparative Study With 4.74-T Magnetic Resonance Imaging and Optical Microscopy
TLDR
Phase-contrast X-ray computed tomography with an interferometer clearly demonstrated the inner structures of colon cancer masses in a similar way to low-magnified optical microscopic images and had approximately 4.0-fold higher signal-to-noise ratio than MRI.
Imaging of Rabbit VX-2 Hepatic Cancer by Cold and Thermal Neutron Radiography
TLDR
Hepatic vessels and VX-2 tumor were clearly observed by neutron radiography, especially by cold neutron imaging, and the image contrast of this modality was better than that of absorption-contrast X-ray radiography.
Cerebral perfusion imaging of live mice by fluorescent X-ray CT
TLDR
In-vivo FXCT imaging with high resolution allows starting to new approach of bio-imaging research, and the structure of extracted mouse brain fixed by formalin was depicted much clearly.
Vessel Imaging by Interferometric Phase-Contrast X-Ray Technique
TLDR
Phase-contrast x-ray imaging explored clear depiction of the vessels using physiological saline with small doses of x-rays with great potential to reveal the structures inside soft tissues.
Tc-99m diethylenetriamine pentaacetic acid (DTPA)-human serum albumin (HSA) radionuclide lymphography for detecting the location of chyluria
The cause of chyluria cannot be easily detected by CT scan or other imaging methods, except conventional lymphography, but Tc-99m diethylenetriamine pentaacetic acid radionuclide lymphography clearly
Imaging renal structures by X-ray phase-contrast microtomography.
TLDR
X-ray crystal interferometer-based X-ray phase-contrast microtomography can detect small scattered lesions in diseased kidney tissue and is a powerful auxiliary tool for pre-histological evaluations.
...
...