Jennifer Milburn

Learn More
PURPOSE Effective parental education about newborn blood-spot screening may facilitate prompt follow-up, reduce psychosocial harms, and promote trust in screening programs. However, little is known about the aspects of education delivery and content that are of most importance for fostering understanding and meeting parental expectations. We aimed to(More)
BACKGROUND The risk of psychosocial harm in families of infants with false-positive (FP) newborn bloodspot screening (NBS) results for cystic fibrosis (CF) is a longstanding concern. Whether well designed retrieval and confirmatory testing systems can mitigate risks remains unknown. METHODS Using a mixed-methods cohort design, we obtained prospective(More)
BACKGROUND Medium chain acyl-CoA dehydrogenase deficiency (MCADD) is a disorder of mitochondrial fatty acid oxidation and is one of the most common inborn errors of metabolism. Identification of MCADD via newborn screening permits the introduction of interventions that can significantly reduce associated morbidity and mortality. This study reports on the(More)
We describe and report first results from PALM-3000, the second-generation astronomical adaptive optics facility for the 5.1-m Hale telescope at Palomar Observatory. PALM-3000 has been engineered for high-contrast imaging and emission spectroscopy of brown dwarfs and large planetary mass bodies at near-infrared wavelengths around bright stars, but also(More)
HD 8673 hosts a massive exoplanet in a highly eccentric orbit (e = 0.723). Based on two epochs of speckle interferometry a previous publication identified a candidate stellar companion. We observed HD 8673 multiple times with the 10 m Keck II telescope, the 5 m Hale telescope, the 3.63 m Advanced Electro-Optical System telescope, and the 1.5 m Palomar(More)
The Caltech HIgh-speedMulti-colour camERA (CHIMERA) is a new instrument that has been developed for use at the prime focus of the Hale 200-inch telescope. Simultaneous optical imaging in two bands is enabled by a dichroic beam splitter centred at 567 nm, with Sloan u′ and g′ bands available on the blue arm and Sloan r′, i′ and z_s bands available on the red(More)
PURPOSE Newborn screening (NBS) for cystic fibrosis (CF) can identify carriers, which is considered a benefit that enables reproductive planning. We examined the reproductive impact of carrier result disclosure of NBS for CF. METHODS We surveyed mothers of carrier infants after NBS (Time 1) and 1 year later (Time 2) to ascertain intended and reported(More)
The Caltech HIgh-speed Multi-color camERA (CHIMERA) is a new instrument that has been developed for use at the prime focus of the Hale 200-inch telescope. Simultaneous optical imaging in two bands is enabled by a dichroic beam splitter centered at 567 nm, with Sloan u′ and g′ bands available on the blue arm and Sloan r′, i′ and z s′ bands available on the(More)
The red channel of the Palomar Double Spectrograph (DBSP) on the 200-inch Hale Telescope has been upgraded with a new deep-depletion CCD from LBNL. Its redder response produced a significant increase of the throughput above 550 nm, and its longer dimension more than doubled the spectral coverage. A special Dewar was designed to accommodate a detector mount(More)
The Zwicky Transient Facility Camera (ZTFC) is a key element of the ZTF Observing System, the integrated system of optoelectromechanical instrumentation tasked to acquire the wide-field, high-cadence time-domain astronomical data at the heart of the Zwicky Transient Facility. The ZTFC consists of a compact cryostat with large vacuum window protecting a(More)