AIM Cryoballoon ablation (Cryoballoon) has emerged as a new alternative for the treatment of symptomatic drug-refractory atrial fibrillation (AF). Whether the results of Cryoballoon are more reproducible than those of radiofrequency (RF) ablation remains to be proved. METHODS AND RESULTS A total of 860 consecutive patients undergoing a first ablation(More)
Cardiac resynchronization therapy has been proposed to alleviate heart failure symptoms refractory to classic drug treatment. Potential benefits hinge on a number of key components, including judicious selection of patients likely to respond to the therapy and appropriate placement of the leads, particularly the lead responsible for left ventricular pacing.(More)
AIMS The choice of resynchronization therapy between with (CRT-D) and without (CRT-P) a defibrillator remains a contentious issue. Cause-of-death analysis among CRT-P, compared with CRT-D, patients could help evaluate the extent to which CRT-P patients would have additionally benefited from a defibrillator in a daily clinical practice. METHODS AND RESULTS(More)
INTRODUCTION The study was designed to evaluate the feasibility and performance of right ventricular (RV) mid-septal versus apical implantable defibrillator (ICD) lead placement. METHODS AND RESULTS SEPTAL is a randomized, noninferiority trial, which randomly assigned patients to implantation of ICD leads in the RV mid-septum versus apex, with a primary(More)
PURPOSE The EVOCAV(DS) trial aimed to quantify the paradoxal atrioventricular (AV) conduction time lengthening in sinus node (SD) patients (pts) paced in AAIR-based pacing mode. METHODS SD pts, implanted with dual-chamber pacemaker programmed in AAIR-based pacing mode, were randomized in two arms for a 1-month period: the low atrial pacing (LAP; basic(More)
INTRODUCTION Failure to enter the coronary sinus (CS) with a guiding catheter and entering its tributaries remains challenging in left ventricle (LV) pacing lead implants for cardiac resynchronization therapy (CRT). A dual telescoping catheter system (8F outer/6F inner) is designed to provide the ability to adjust the catheter curve size, shape and/or reach(More)
Recent data show no benefit of additional ablation beyond pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF). Evidence suggests that radiofrequency energy (RF) and cryoballoon (CRYO) have comparable efficacy for PVI. We aimed to assess the outcomes after a single catheter ablation procedure, comparing PVI using CRYO vs. RF ablation for(More)