A difficult challenge in geometrical acoustic modeling is computing propagation paths from sound sources to receivers fast enough for interactive applications. This paper describes a beam tracing method that enables interactive updates of propagation paths from a stationary source to a moving receiver in large building interiors. During a precomputation(More)
Very little reliable information exists on the sound levels present in an operating room environment. To remedy this situation, sound pressure levels of the operating rooms in Johns Hopkins Hospital were monitored before, during, and after operations. The data were analyzed to determine background sound levels, average equivalent sound levels L(eq),(More)
This article presents the results of a noise survey at Johns Hopkins Hospital in Baltimore, MD. Results include equivalent sound pressure levels (L(eq)) as a function of location, frequency, and time of day. At all locations and all times of day, the L(eq) indicate that a serious problem exists. No location is in compliance with current World Health(More)
Analysis of the external brachial pulse recorded during standard blood pressure cuff deflation with use of a transducer with a wide frequency response has revealed a reproducible pattern with three distinct components that we have labeled K1, K2, and K3. K1 is a low-amplitude, low-frequency signal that is present with cuff pressures above systolic pressure.(More)
Controversy exists concerning the most accurate method for defining diastolic blood pressure in pregnancy. Both disappearance (phase V) and muffling (phase IV) of Korotkoff sounds have been advocated. We previously reported an objective noninvasive method for measuring blood pressure, called K2 analysis, which in nonpregnant subjects was not different from(More)
While hospitals are generally noisy environments, nowhere is the pandemonium greater than in an emergency department, where there is constant flow of patients, doctors, nurses, and moving equipment. In this noise study we collected 24 h measurements throughout the adult emergency department of Johns Hopkins Hospital, the top ranked hospital in the U.S. for(More)
A foil electret microphone for use under the cuff of an automatic blood pressure monitoring system is described. The transducer is designed to operate with relatively flat sensitivity over a static pressure range of 40 to 250 mm Hg (5.33 X 10(4) to 3.33 X 10(5) dyn/cm2). The new electret microphone differs from conventional microphones used for airborne(More)
Not infrequently, blood pressure measurement by the standard auscultatory technique yields a normal systolic pressure with an elevated diastolic pressure. The relatively narrow pulse pressure of such a measurement raises concern about the accuracy of the blood pressure measurement. The purpose of this study was to assess the accuracy of auscultatory blood(More)