• Publications
  • Influence
Three-Dimensional Intravascular Ultrasound Assessment of Abdominal Aortic Aneurysm Necks
Purpose: To document the accuracy of an automated analysis system for measuring lumen diameter and neck lengths of abdominal aortic aneurysms (AAAs) from intravascular ultrasound (IVUS) images and toExpand
  • 17
  • 1
Endovascular Stent-Grafts for Aneurysms of the Femoral and Popliteal Arteries
n= 2); a true aneurysm of the popliteal artery (n= 4); an aneurysmal dilatation of a Biograft bypass (n= 2); a false aneurysm of the superficial femoral aneurysm (n= 1); and a false aneurysm of aExpand
  • 45
Displacement Sensing Device Enabling Accurate Documentation of Catheter Tip Position
The need for reproducible positioning of an intravascular ultrasound catheter tip before and after intervention in relation to the angiographic records, resulted in the development of a dedicatedExpand
  • 32
Temporal correlation of blood scattering signals in vivo from radiofrequency intravascular ultrasound.
One limitation encountered using high frequency intravascular ultrasound (IVUS) is the echogenicity of blood, which increases dramatically at frequencies of 20-40 MHz. Because of the higher velocityExpand
  • 47
  • PDF
Discrepancy between stent deployment and balloon size used assessed by intravascular ultrasound.
OBJECTIVES This study was designed to assess the discrepancy in stent deployment seen on intravascular ultrasound and its relation to the balloon size selected for stent delivery. DESIGNExpand
  • 9
Plaque area increase and vascular remodeling contribute to lumen area change after percutaneous transluminal angioplasty of the femoropopliteal artery: an intravascular ultrasound study.
OBJECTIVE The aim of the study was to assess the change in lumen area (LA), plaque area (PLA), and vessel area (VA) after percutaneous transluminal angioplasty (PTA) of the femoropopliteal artery. Expand
  • 21
Validation of transrectal ultrasonographic volumetry for orthotopic prostate tumours in mice
Orthotopic human prostate tumour models in athymic nude mice are regarded as being most suitable for fundamental and pre-clinical research on prostate cancer. The anatomic localization of the tumourExpand
  • 30
Reproducibility of volumetric quantification in intravascular ultrasound images.
The reproducibility of volume measurements in intravascular ultrasound (IVUS) images derived from separate pull-back manoeuvres remains to be elucidated. Patients (n = 23) were imaged with IVUS priorExpand
  • 27
Early Experience with Intravascular Ultrasound in Evaluating the Effect of Statins on Femoropopliteal Arterial Disease: Hypothesis-Generating Observations in Humans
The purpose of this study was to compare the vascular response seen with intravascular ultrasound (IVUS) at 1-year follow-up between statin-treated and non–statin-treated patients. Patients (n=10)Expand
  • 7
Arterial wall strength after endovascular photodynamic therapy
Vascular photodynamic therapy (PDT) inhibits intimal hyperplasia (IH) induced by angioplasty in rat iliac arteries by eradicating the proliferating smooth muscle cells. This process may jeopardiseExpand
  • 7
  • PDF
...
1
2
3
...