Development and validation of ultrasound speckle tracking to quantify tendon displacement.
TLDR
A dedicated two-dimensional multi-kernel block-matching scheme with subpixel motion estimation was devised to handle large displacements over long sequences. Expand
  • 109
  • 8
Ultrasonographic assessment of long finger tendon excursion in zone v during passive and active tendon gliding exercises.
PURPOSE Cadaver and in vivo studies report variable results for tendon excursion during active and passive hand movements. The purpose of this study was to measure long finger flexor digitorumExpand
  • 36
  • 4
  • PDF
Current status and future developments of contrast-enhanced ultrasound of carotid atherosclerosis.
B-mode and Doppler ultrasound are commonly used for the evaluation of atherosclerosis in the carotid arteries. Recently, contrast-enhanced ultrasound (CEUS) has been introduced as a technique toExpand
  • 75
  • 3
Azimuthal Registration of Image Sequences Affected by Nonuniform Rotation Distortion
TLDR
We present a new method to correct the effects of variations of the rotation speed in OCT image sequences, known as NURD. Expand
  • 42
  • 3
  • PDF
A Prototype PZT Matrix Transducer With Low-Power Integrated Receive ASIC for 3-D Transesophageal Echocardiography
This paper presents the design, fabrication, and experimental evaluation of a prototype lead zirconium titanate (PZT) matrix transducer with an integrated receive ASIC, as a proof of concept for aExpand
  • 48
  • 3
A front-end ASIC with receive sub-array beamforming integrated with a 32 × 32 PZT matrix transducer for 3-D transesophageal echocardiography
  • C. Chen, Z. Chen, +11 authors M. Pertijs
  • Engineering, Computer Science
  • IEEE Symposium on VLSI Circuits (VLSI-Circuits)
  • 15 June 2016
TLDR
This paper presents a power- and area-efficient front-end ASIC that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable the next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. Expand
  • 31
  • 3
Dedicated ultrasound speckle tracking to study tendon displacement
Ultrasound can be used to study tendon and muscle movement. However, quantization is mostly based on manual tracking of anatomical landmarks such as the musculotendinous junction, limiting theExpand
  • 12
  • 3
Cardiac Shear Wave Velocity Detection in the Porcine Heart.
Cardiac muscle stiffness can potentially be estimated non-invasively with shear wave elastography. Shear waves are present on the septal wall after mitral and aortic valve closure, thus providing anExpand
  • 38
  • 2
Subharmonic, non-linear fundamental and ultraharmonic imaging of microbubble contrast at high frequencies.
There is increasing use of ultrasound contrast agent in high-frequency ultrasound imaging. However, conventional contrast detection methods perform poorly at high frequencies. We performed systematicExpand
  • 21
  • 2
Myocardial passive shear wave detection
We studied the mechanical waves after mitral and aortic valve closure in the septal wall of 34 pigs (18 diabetic for heart failure and 16 controls), using high frame rate imaging on a programmableExpand
  • 8
  • 2
...